Taylor C300 Operator's Manual page 22

Slush freezer
Table of Contents

Advertisement

USER INTERFACE
BRL NOT COOLING—A freezing cylinder check has
been established for the AUTO mode of operation. If a
freezing cylinder enters the AUTO mode, the control will
check product temperature. After five minutes, it will
again check product temperature. If product temperature
does not drop in that 5-minute time span, the freezing
cylinder will shut down and this message will appear on
the fault screen. For this check to be valid, the product
temperature must be above 40°F (4.4°C).
FAULT DESCRIPTION
L: BARREL NOT COOLING
R: NO FAULT FOUND
CLR
BRL TEMP 2 HIGH—A maximum allowable product
temperature has been established to prevent product
from excessive heating. If the product exceeds 120°F
(49°C) for any reason (in any mode of operation), the
entire unit shuts down.
FAULT DESCRIPTION
5
L: BARREL TEMP 2 HIGH
R: NO FAULT FOUND
CLR
Faults, when corrected, are cleared from the FAULT
DESCRIPTION screen, with the following exception: BRL
NOT COOLING. This fault requires the operator to press
the OFF (<- -) key (when in the FAULT DESCRIPTION
screen) in order for the fault to discontinue.
To see if there is more than one fault in either freezing
cylinder, press the PRIME (+ + +) key. To return to the
operator menu, press the MENU (SEL) key once. To
return to the Main Screen, use the AUTO (- ->) key to
cycle to menu item A, then press the MENU (SEL) key.
5-4
+ + +
SEL
+ + +
SEL
Screen C—SET CLOCK
Use the AUTO (- ->) and OFF (<- -) keys to place the
cursor under the element to be set (hours, minutes,
month, day, or year). Use the PRIME (+++) and BEATER
(- - -) keys to increment or decrement the value. Press
the MENU (SEL) key to advance to the Daylight Saving
Time screen.
Note:
The clock is programmed with military time.
SET CLOCK
14
3 :
0
<- - - -> + + +
This screen will appear if an invalid date is entered
(example: if the date entered exceeds the days of that
month).
SET CLOCK
14
3 :
0
This screen allows the Daylight Saving Time options. If
the Daylight Saving Time option is enabled, then the time
will be advanced by one hour at 2:00 a.m. on the first
Sunday in April, and will be retarded by one hour at 2:00
a.m. on the last Sunday in October.
DAYLIGHT SAVING TIME
ENABLE
<
- -
-
> -
Screen D—MANUAL DEFROST
This screen allows the operator to manually defrost the
left or right side of the unit.
Place the cursor under YES, press the MENU (SEL) key,
and the command will be executed.
MANUAL DEFROST
L
E
F
T
S
D I
E
<
- -
-
> -
Model C300
1
0
- - -
SEL
0
2
INVALID DATE
DISABLE
Y
E
S
User Interface
2 /
5
0 /
6
3 /
1
0 /
7
SEL
S
E
L
NO
S
E
L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents