NO FAULT FOUND—No fault conditions are apparent.
FAULT DESCRIPTION
L:
NO FAULT FOUND
R:
NO FAULT FOUND
CLR
+ + +
BEATER OVERLOAD—Beater motor is out on overload.
When this fault occurs, the machine automatically turns
off. The fault clears when the condition is corrected.
FAULT DESCRIPTION
L: BEATER OVERLOAD
R: BEATER OVERLOAD
CLR
+ + +
CHK REFRIG SYS PSI—Compressor is out on high
head pressure. When this fault occurs, the machine
automatically turns off. The fault clears when the
condition is corrected.
FAULT DESCRIPTION
L: CHK REFRIG SYS PSI
R: CHK REFRIG SYS PSI
CLR
+ + +
THERMISTOR SHORT—One or both of the barrel
(freezing cylinder) thermistor probes are faulty.
FAULT DESCRIPTION
L: THERMISTOR SHORT
R: NO FAULT FOUND
CLR
+ + +
THERMISTOR OPEN—One or both of the barrel
(freezing cylinder) thermistor probes are faulty.
FAULT DESCRIPTION
L: THERMISTOR OPEN
R: NO FAULT FOUND
CLR
+ + +
User Interface
SYRUP PRESS LOW—When the syrup out indicator
displays a lack of syrup, the unit will enter a Hold mode.
At this time, no refrigeration or product flow from the flow
control will be allowed. Only the beater will operate.
When the syrup is satisfied, the unit will refill the product
tank, and then automatically return to the Auto mode.
SEL
The fault message and the warning tone will clear.
FAULT DESCRIPTION
L: NO FAULT FOUND
R: SYRUP PRESS LOW
CLR
CO
PRESSURE LOW—When the CO
2
displays a lack of CO
SEL
start. If the CO
seconds, both freezing cylinders will shut down, and this
fault message will appear. Replenish the CO
fault message and warning tone will clear.
FAULT DESCRIPTION
L: CO2 PRESSURE LOW
R: CO2 PRESSURE LOW
CLR
SEL
O PRESSURE LOW—When the water out 
H
2
indicator displays a lack of water, a 60-second 
internal timer will start. If the water is not replenished at
the end of the 60 seconds, all freezing cylinders will shut
down, and this fault message will appear. Replenish the
water, and the fault message and warning tone will clear.
SEL
FAULT DESCRIPTION
L: H2O PRESSURE LOW
R: H2O PRESSURE LOW
CLR
SEL
Model C300
USER INTERFACE
+ + +
out indicator
2
, a 60-second internal timer will
2
is not replenished at the end of the 60
2
+ + +
+ + +
SEL
and the
2 ,
5
SEL
SEL
5-3