ACCESSORIES
KODAK EKTAPRO High Gain Imager
This Imager will provide approximately 1 f-stop more sensitivity in
the HIGH GAIN mode as compared to the NORMAL mode.
The selection switch for HIGH GAIN or NORMAL gain is located
on the bottom of the Imager rear cover.
The Imager should be in the NORMAL position when the Proces-
sor is powered on.
Gain Switch
NORMAL
HIGH GAIN
RECORD
STOP
When HIGH GAIN is selected, the picture will change intensity
and flicker while the Processor power supply stabilizes. After the
power supply stabilizes, the picture will be approximately 1 f/stop
more sensitive. You may notice a slight decrease in picture quality
when the Imager is operated in High Gain. This is considered
standard operation.
When NORMAL is selected, the picture will change intensity and
flicker while the Processor power supply stabilizes. After the
power supply stabilizes, the Imager and Processor will be operat-
ing in the normal mode.