Configuration setting Niveau.ini
The file Niveau.ini saves the COM-Port (COM 3 [de-
fault]). The measured values can be read in the main
program by an inclination measering device. The file
Niveau.ini saves the number to which the inclination
measering device is connected.
COM3 = Default
COM1 = assigned by a remote control recipient COM2 =
assigned through the measurement box
COM3 = free for inclinometer
COM4 = free
INI-file of the main program
[LanguageServer] ILSV = language server
Entry
Legend
Address=localhost
Address = Local hard disk
Port=1096
Port address for server inquiry
Tab. 10:
[CCDServer] CCD = measured data-server
Entry
Legend
Address=localhost
Address = Local hard disk
Port=1081
Port address for server inquiry
Tab. 11:
[DemoServer] Demo server
Entry
Legend
Address=localhost
Address = Local hard disk
Port=1082
Port address for server inquiry
Tab. 12:
[LicenceServer] Lizenz-Server
Entry
Legend
Port=1085
Port address for server inquiry
Tab. 13:
[MeasurementSystemSetup] Einstellung Messsystem
Entry
Legend
Equipment out of tolerance =
OutOfTolerance=600
600" =10' angle minutes
Tab. 14:
i
Only relevant settings are mentioned.
Robert Bosch GmbH
Operating System-Software | FWA 43xx / 44xx | 49
14.11.3

CCD server

Fig. 16:
CCD server
Tasks
R
Separate Program module
R
Server for main program
R
Provision of real-time measured values (currently
measured in the vehicle)
R
Start before the main program
R
In case of manual start, begin before the main
program
R
Interface between the main program and the
charging station and/or the sensors.
The role is to execute measuring tasks, which are
transferred from the main program to the server via a
TCP/IP-connection. The CCD server translates these
measuring tasks into the measuring system-specific
commands, and transmits these to the sensor via the
serial interface (RS232) of the charging station. The
measured values and status information required by the
main program are generated from the result, and sent
to the main program once again via the TCP/IP .
Function
R
The CCD server is a separate program module.
R
The CCD server contains diagnostic functions and
a dialogue to edit configuration settings.
Path/program file
R
C:\<program files>\FWA-CCD\WheelAligner\CCD
R
CCD.exe
Program start
R
Auto Start-Group
File description
R
CCD.EXE - Executable program file
R
CCD.INI - Configuration settings of the CCD server
en
|
1 690 326 006
2008-8-25

Hide quick links: