Graph" Tab; Further Executable Functions Via "Actions - Bosch FWA 43 Series Maintenance Instructions Manual

Wheel alignment system
Table of Contents

Advertisement

en
46 | FWA 43xx / 44xx | Operating System-Software
14.9.6

"Graph" tab

Fig. 10:
Signal response of the CCD servers
1 Selecting the camera.
2 Determines whether the graph is displayed or whether only the
measuring value is determined.
3 Resolution of the detail field, refer to description (9).
4 Status after reading: "Ok" or "Failed" (error).
5 The determined measuring value.
6 Progress indicator, while reading the data.
7 Position (X) and value (Y) of maximum amplitude of the
Hell(Bright) image and Differenz (Diff) image.
8 Displays the signal response of the entire CCD sensor.
9 Detail field. Displays details of the signal response in the set
resolution symmetrically for maximum amplitude.
14.9.7

Further executable functions via "Actions"

Options
Read toe pictures
Read camber picture
Tab. 8:
Further functions via Actions
"Coefficients" tab
The camera specific parameters required for correct
determination of the measuring values are displayed on
this page.
The parameters are (reflected) saved in the camera
processor and/or measuring processor and is displayed
in different display blocks (compare colour scheme in
case of "Type and version info").
|
1 690 326 006
2008-8-25
Legend
The data of toe-in/out is read
for the selected camera.
The data of camber
measurement is read for
the selected camera.
Fig. 11:
Camera specific parameter
1 Coefficient for calculating track measurement value. In case
calibration sets the value "Toe x**0".
2 Coefficient for calculating camber measurement value. In case
calibration sets the value "Camber x**0".
3 Date of last calibration.
4 Displays whether the fields "Lens Corr." and "Pendulum Corr."
have a valid value.
AA = valid value for "Lens Corr."
55 = both fields include valid values.
5 Correction value for the lens inclination.
6 Correction value for the camber.
The column "Hex" displays the image of the value in the memory
of the camera processor, the column "Value" displays the
corresponding numerical values.
i
The functions that be called via "Actions" are
identical to the tab "Type and version info".
Options
Legend
Write toe zero
Writes a standard value for the
correction defaults
coefficients "Toe x**0" in the EEROM
of the selected camera processors.
Thus the problem can be solved, as
calibration is not possible because
the current value is invalid.
Write camber zero
Writes a standard value for
correction defaults
the coefficients "Camber x**0"
in the EEROM of the selected
camera processors.
Thus the problem can be solved, as
calibration is not possible because
the current value is invalid.
Tab. 9:
Further functions via Actions (Service variant)
i
The options function only with the service version of
the Sysmonitor.
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fwa 44 series

Table of Contents