Pacific energy granville Installation And Operating Instructions Manual

Pacific energy granville Installation And Operating Instructions Manual

Direct vent insert series a

Advertisement

IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
f i r e - p a r t s . c o m
• WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do
not use any phone in your building.
- Immediately call your gas supplier
from a neighbour's phone. Follow the
gas supplier's instructions.
- If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
040805-24
Granville

Direct Vent Insert

INSTALLATION
AND OPERATING
INSTRUCTIONS
GRNA
SERIES A
# 5055.651

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the granville and is the answer not in the manual?

Questions and answers

Summary of Contents for Pacific energy granville

  • Page 1: Direct Vent Insert

    Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. Granville • Installation and service must be performed by a qualified installer, service agency or the gas supplier. Direct Vent Insert...
  • Page 2: Table Of Contents

    Contents Caution ..................3 Safety ..................3 Maintenance ................3 Installation ................. 4 Clearances .................. 5 Venting ..................6 Rocker Switch ................7 Gas Supply ................. 8 Burner Removal ................. 9 Levelling Legs ................9 Log Set ..................10 Surround Assembly ..............12 Glowing Embers ..............13 f i r e - p a r t s .
  • Page 3: Caution

    FOR YOUR SAFETY - Do not install or operate your Pacific Caution: Turn off gas and electrical power supply and allow Energy Granville Direct Vent Gas Insert without first reading ample time for unit to cool before servicing appliance. It is and understanding this manual.
  • Page 4: Installation

    Existing Fireplace (Masonry or Factory Built) The Granville Direct Vent Gas Insert is designed to be installed into a masonry or a factory built zero clearance fireplace. The masonry fireplace must be built according to the requirements of the Standards for Chimneys, Fireplaces,...
  • Page 5: Clearances

    Clearances Fig. # 5 The minimum clearances from the appliance to combustible surfaces are shown on Fig. #4 and #5. Adequate clearances Mantel around air openings and air supplies are required. 12" (305mm) MINIMUM CLEARANCES 18" (457mm) TO COMBUSTIBLES: Adjacent sidewall: ....... 6.0 in. (152 mm) Ceiling to appliance: ....
  • Page 6: Venting

    Venting Fig # 7 Vent Terminal Caution: Only Flex Liner kit (MIND.FL25) or an approved Seal gas vent flue liner and a Vent Terminal (MIND.VTTERM) is approved for use with this appliance. Also approved for use is Simpson Dura-Vent GS termination kits, both Standard Vertical Termination cap (#980) and the Extended Vertical Termination cap (#930) in conjunction with the 3"...
  • Page 7: Rocker Switch

    Make sure the marked inlet pipe is attached to the inlet side (marked "I"), and the unmarked pipe is attached to the Fig # 9 outlet side (marked "E") of the connector plate. 7) Seal and secure inlet pipe with sealant and screws pro- vided.
  • Page 8: Gas Supply

    Gas Supply An optional 24" long flexible connector (part # Caution: The gas line should be installed by a qualified GASC.GASCON) may be used for easy gas connection. This service person in accordance with all building codes. connector may exit the appliance through either the right front Consult local and/or national building codes before pro- or right rear access holes.
  • Page 9: Burner Removal

    Burner Removal Fig # 13 Caution: Turn off gas and electrical power supply and allow ample time for unit to cool before proceed- ing. 1) Fold down the bottom louver, if installed, to access the over-center latch. Disengage the latches by pulling each lever down and forward.
  • Page 10: Log Set

    Log Set Fig. # 15a Log Tabs The Ceramic logs are durable and long lasting when installed properly. However, they are deli- cate and may be damaged easily if not handled with care. Unpack and inspect log set. There should be a total of 7 logs.
  • Page 11 Fig. # 15d Step 5 Top Right Log Placement (log #5) Fig. # 15e Step 7 Rear Right Log Placement (log #7) Step 6 Rear Left Log Placement (log #6) f i r e - p a r t s . c o m Fig.
  • Page 12: Surround Assembly

    Surround Assembly Fig. # 17 Fig. # 18 1) Lay Parts A, B, and C face down on a flat, non-marking surface. (Fig. #16) Fasten together with spring clips through holes at points "D". (Fig. #19) 2) Lift the surround assembly to the upright position and make sure the front face is even at the joint.
  • Page 13: Glowing Embers

    Glowing Embers Fig. # 22 Note: Use only glowing embers supplied with the appliance. Use of any other materials or incorrectly placed embers may cause an incorrect flame pattern, sooting and/or delayed ignition. Place 10 to 12 pieces randomly on the front burner area as shown in figure #22.
  • Page 14: Lighting Instructions

    Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING phone in your building. WARNING: If you do not follow these - Immediately call your gas supplier from a neigh- instructions exactly, a fire or explosion bour's phone. Follow the gas supplier's instruc- may result causing property damage, tions.
  • Page 15: First Fire

    Set the wall thermostat to a comfortable temperature. Turn the HI-LO burner control knob to a desired setting. As heat is required, the Granville Direct Vent Insert will turn on or off automatically, as needed. Fig. # 27...
  • Page 16: Optional Blower

    Optional Blower Optional Blower Fig. # 29 Installation: The burner assembly must be removed for blower kit installation. Follow "Burner Removal" section for removal. Unpack and inspect blower kit. 1) Position the blower assembly over the two studs located at the rear of the appliance so that the fan motor is facing towards the front.
  • Page 17: Optional Radiant Overlay

    Optional Radiant Overlay Fig. # 31 Trim The optional Radiant Overlay may be installed at any time. Unpack and inspect all parts. Install Overlay as follows: 1) Remove the glass frame assembly from the appliance if installed. Place face up on a flat, stable surface to avoid damage.
  • Page 18: Replacement Parts

    * Standard-size Surround Assembly, Plain and Embossed Bevelled Panels ....... 38 1/2" wide x 27 1/4" high ** Over-size Surround Assembly, Plain Flat Panels ............44 3/4" wide x 30 1/2" high All parts may be ordered from your nearest Pacific Energy dealer. Contact Pacific Energy for the location of the dealer nearest you.
  • Page 19 Fig. # 32 f i r e - p a r t s . c o m 040805-24 GRNA # 5055.651...
  • Page 20: Burner Replacement Parts

    26 ..Pilot Bracket ..........1866 f i r e - p a r t s . c o m All parts may be ordered from your nearest Pacific Energy Gas Stove dealer. Contact Pacific Energy for the location of the dealer nearest you.
  • Page 21: Direct Vent Terminal Kit

    Appendix A Direct Vent Terminal Kit MIND.VTTERM Please refer to the Installation Instructions provided with the appliance for proper installation. This box contains: 1 ..Vent Terminal f i r e - p a r t s . c o m 4 ..#10 x 5/8"...
  • Page 22: Vent Terminal Flashing Installation Guide

    Vent Terminal Flashing Installation Guide MIND.FLASH This kit contains: 1 ..Vent Terminal Flashing 4 ..#8 x 1" Sheet Metal Screws f i r e - p a r t s . c o m Installation: Attach the vent terminal to the flashing Attach the flashing to the chimney, by first using the 4 screws provided.
  • Page 23: Safety Label

    Rating Label f i r e - p a r t s . c o m Propane Conversion Rating Label 040805-24 GRNA # 5055.651...
  • Page 24 - p a r t s . c o m Pacific Energy Fireplace Products Ltd. 2975 Allenby Rd, Duncan, BC V9L 6V8 Phone: 250-748-1184 Web site: http://www.pacificenergy.net Printed in Canada...

Table of Contents