WIRING DIAGRAM

NOTE: THESE INSTRUCTIONS ARE SPECIFICALLY FOR
DV**PEC MODELS. DO NOT ATTEMPT TO APPLY THESE
DIAGRAMS FOR ANY OTHER MODELS.
(SEE NOTE 4)
TO
GROUND LUG
HEATER KIT
9
8
7
6
5
4
C
O
M
RD
BK
RD
BK
BL
1
2
INSTALLING
WH
AUX ALARM
(ALARM)
~ ~
(SEE NOTE 9)
TB4
BR
~ ~
TB5
RELAY OUT
BL
(ACC-OUT)
RELAY IN
(ACC-IN)
HEATER KIT
OUTPUT
NOTES:
1. PLACE RED WIRES ON 208 V TERMINAL OF
2-TRANSFORMER (TR1/TR2) FOR 208 VAC
OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT
PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS
SUPPLIED WITH THIS UNIT MUST
BE REPLACED, IT MUST BE REPLACED
WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED
AND CONFORM TO N.E.C ANDLOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST
RECENT TO LEAST RECENT, DEPRESS
FAULT RECALL BUTTON FOR MORE THAN 2
SECONDS WHILE IN STANDBY (NO THERMOSTAT
INPUTS)
6. RED STATUS LED PROVIDES NETWORK STATUS.
GREEN RX LED INDICATES NETWORK TRAFFIC.
USE LEARN BUTTON TO RESET NETWORK.
7. DISCARD CONNECTOR PL1 WHEN
INSTALLING OPTIONAL HEAT KIT.
8. THE POSITION OF SELECTOR SWITCHES
(DS1 - DS6) INDICATE FACTORY SETTING.
9. REMOVE SHORT RED CIRCUITING WIRE AND
PUT AUX ALARM SWITCH WHEN INSTALLING AUX
ALARM SWITCH.
10. USE N.E.C CLASS 2 WIRE.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
208/230
VAC
(SEE NOTE 7)
RD
BK
PL1
3
2
1
PL2
BK
RD
BK
RD
208
208
230
230
VAC
VAC
VAC
C
O
M
VAC
TR1
TR2
(SEE NOTE 1)
(SEE NOTE 1)
24VAC
24VAC
PU
YL
RD
PL3
3
4
5
6
7
8
9
10
11
12
PL4
RD
BK
AUX ALARM
AUX ALARM
(ALARM)
(ALARM)
GR
GR
TR1
TR1
TB4
TB4
TH1
TH1
TB5
TB5
O
O
Y2
Y2
Y1
Y1
W2
W2
TB2
TB2
TB1
TB1
DEHUM
DEHUM
X8A
X8A
ACC-OUT
ACC-OUT
F2U
F2U
TB8
TB8
COM
X12A
X12A
X13A
X13A
ACC-IN
ACC-IN
TB7
TB7
TB6
TB6
(SEE NOTE 6)
TH2
TH2
TR2
TR2
TB10
TB10
TB3
TB3
PS
PS
F1U
F1U
CPU LED
CPU LED
STATUS LED
(SEE NOTE 6)
K1R
K1R
X2A
X2A
DS6
DS6
K2R
K2R
SEG2
SEG2
(SEE NOTE 5)
FAULT RECALL
X1A
X1A
BS2
BS2
SEG1
SEG1
X3A
X3A
X15A
X15A
X5A
X5A
BS1
BS1
(SEE NOTE 6)
LEARN
LEARN
OR
OR
EEV
EEV
BL
BL
YL
YL
RD
RD
BK
BK
THERMISTOR
THERMISTOR
M
M
(HEAT EXCHANGER 1,2)
(HEAT EXCHANGER 1,2)
PRESSURE
PRESSURE
INTEGRATION
INTEGRATION
SENSOR
SENSOR
EEV
EEV
TYPE
TYPE
COIL
COIL
INTEGRATED CONTROL:
LOW VOLTAGE
LOW VOLTAGE FIELD
HIGH VOLTAGE
HIGH VOLTAGE FIELD
INTERNAL TO
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
EQUIPMENT GND
FIELD GROUND
HIGH VOLTAGE! DISCONNECT ALL POWER 
BEFORE SERVICING. MULTIPLE POWER 
SOURCES MAY BE PRESENT. FAILURE TO DO SO 
MAY CAUSE PROPERTY DAMAGE, PERSONAL 
INJURY OR DEATH.
ECM MOTOR
FAN
MOTOR
RD
BK
GY
BL
THERMOSTAT
GY BK
R
C
C
R
R
G
G
2
2
1
1
W1
W1
W1
W2
RX LED
RX LED
X7A
X7A
Y1
Y2
DS5
DS5
MPU
MPU
G
DS4
DS4
O
DS1
DS1
DS2
DS2
DS3
DS3
DEHUM
ON OFF
ON OFF
INDOOR UNIT
INDOOR UNIT
C
PCB
PCB
COLOR CODES:
BL - BLUE
RD - RED
YL - YELLOW
OR - ORANGE
BK - BLACK
JUNCTION
GY - GREY
TERMINAL
BR - BROWN
GR - GREEN
RESISTOR
PU - PURPLE
WH - WHITE
24
L1
GRND
DISCONNECT
INDOOR
AIR
CIRCULATOR
BLWR
208/230 VAC
L1
FUSE 3 A
TH
24 VAC
W1 (1)
HEAT 1 COIL/R1
W2 (2)
HEAT 2 COIL/ R2
CAS (1)
CONDENSATE SWITCH
CAS (2)
TO
MICRO
+VDC (1)
RX (2)
TX (3)
GRND (4)
TR
COM
INTEGRATED CONTROL MODULE
COMPONENT CODES:
POWER/HEATER
PL1, PL2
CONNECTOR
DS1 - DS6
SELECTOR SWITCH
TL
THERMAL LIMIT
TR
TRANSFORMER
F1U, F2U
FUSE LINK
L2
GRND
L2
40 VA
TRANSFORMER
INDOOR
AIR
CIRCULATOR
BLWR
GRND
0140A00501-A