VR1- AUTOMATIC CLOSING
VR1 trimmer sets the automatic closing time (DIP-switch 2 = ON).
The automatic closing time can be adjusted between 1 and 60 seconds.
VR2- FORCE IN OPENING
VR2 trimmer sets the force and the obstacle detection. Turning the trimmer
clockwise the force increases while the obstacle detection decreases. Calibrate the
obstacle detection force properly, to avoid faults during normal operation. We
recommend to start setting the force to minimum and after adjust step by step
VR3- FORCE IN CLOSING
VR3 trimmer sets the force and the obstacle detection. Turning the trimmer
clockwise the force increases while the obstacle detection decreases. Calibrate the
obstacle detection force properly, to avoid faults during normal operation. We
recommend to start setting the force to minimum and after adjust step by step
DIP-switch
DIP-switch 1:
ON - Automatic closing ACTIVATED
OFF - Automatic closing DEACTIVATED
DIP-switch 2:
ON - The flashing light is OFF when the barrier is in stand-by .
OFF - The flashing light is ON when the barrier is in stand-by.
LED Work
OPEN
The barrier is opening
STOP
The barrier is in stand-by
CLOSE
The barrier is closing
LEARN
Transmitter storage in progress
LED Warnings
DS2
Opening completed
DS3
Closing completed
DS4
Safety edge / loop detector operating
DS5
Photocells calibrated
DS1
Barrier powered
9
TIME
VR1
OPEN_FORCE
VR2
CLOSE_FORCE
VR3
S3
LED1
LED2
LED3
OPEN
STOP
CLOSE
DS2
DS3
DS4
DS5
DS1