Proteco BARRY User Manual page 10

Automatic road barrier
Hide thumbs Also See for BARRY:
Table of Contents

Advertisement

VR1 - FORCE
VR1 trimmer sets the force and the obstacle detection. Turning the trimmer clockwise the force
increases while the obstacle detection decreases. If J9 jumper is set right side (ON), the obstacle
detection will stop the barrier during closing and will reverse to opening position. Calibrate the
obstacle detection force properly, to avoid faults during normal operation.
VR2 – AUTOMATIC CLOSING
VR2 trimmer sets the automatic closing time (DIP-switch 2 = ON). The automatic closing time can
be adjusted between 1 and 60 seconds.
DIP-SWITCHES
DIP-switch 1:
ON - Set dip-switch 1 to ON if you need to wire a safety edge (the safety edge shall be wired
as well on terminal PT on the control unit).
OFF – Set dip-switch 1 to OFF if you need to wire a loop detector (the loop detector shall be
wired as well on terminal PT on the control unit).
DIP-switch 2:
ON - Automatic closing ACTIVATED (from 1 to 60 seconds.
OFF - Automatic closing DEACTIVATED.
DIP-switch 3: Void
LED Work
OPEN
The barrier is opening
STOP
The barrier is in stand-by
CLOSE
The barrier is closing
LEARN
Transmitter storage in progress
LED Warnings
OL
Opening completed
CL
Closing completed
PT
Safety edge/loop detector operating
LOOP
Photocells calibrated
POWER
Barrier powered
7
VR1
VR2
S1
OPEN
STOP
CLOSE
OL
CL
PT
LOOP POWER
LEARN

Advertisement

Table of Contents
loading

Table of Contents