  • Page 1 User Manual BARRY AUTOMATIC ROAD BARRIER...
  • Page 3: Table Of Contents

    Index WARNINGS AND INSTALLATION TIPS ........................p. 01 COMPLIANCE DECLARATION ..........................p. 01 TECHNICAL FEATURES ............................. p. 02 INSTALLATION ................................p. 02 Standard layout Basement preparation Fixing the barrier on ground MANUAL OPERATION .............................. p. 03 LOCK AND UNLOCK THE TOP COVER ........................p. 03 BALANCING OF THE BOOM ...........................
  • Page 4: Warnings And Installation Tips

    This product has been designed only for its intended use. Any other use could affect the integrity and safety of the product, therefore has to be considered prohibited. Use only original spare parts. No alteration on the system has to be carried out. Proteco Srl will not respond in case of using additional and/or fake spares.
  • Page 5: Technical Features

    TECHNICAL FEATURES 230V AC 24V DC Main power: 230V 50Hz 230V 50 Hz Motor power supply: 230V ac 24V dc Motor power: 200W 160W Absorption max.: 1,5A 230V 1,2A 230V Opening time: circa 6 secondi circa 6 secondi Automatic closing: da 1 a 60 sec.
  • Page 6: Manual Operation

    MANUAL OPERATION For manual operation pull the hand grip and turn clockwise. Release the hand grip and move manually the boom. During manual operation boom could suddenly lift up: be careful and always hold the boom with your hands to avoid damages. Pull the hand grip and turn clockwise to unlock To lock the system, pull the hand grip and turn...
  • Page 7: Balancing Of The Boom

    BALANCING OF THE BOOM Size the boom length before installation: the boom is modularized, cut or join according the length you need. Fix the boom as shown in the picture. Once the boom is fixed on the barrier and for any reason the length has to be changed, proceed to readjust the springs and the limit switches, in the following way:...
  • Page 8: Limit Switches

    LIMIT SWITCHES The barrier comes with both magnetic and mechanical limit switches, pre-set by factory. Normally it is not necessary to adjust them. However if this were the case, see how to proceed as shown in the below picture: CLOSING position OPENING position MAIN POWER (230V + GROUNDING) The barrier can be powered both 230V and 115V AC, and main power has to be wired as shown in the below picture:...
  • Page 9: Ac Wiring Diagram (230/115Vac)

    AC WIRING DIAGRAM (230/115Vac) OPEN STOP CLOSE LEARN LED WORK LED WARNINGS LOOP POWER PUSH Lights supply FACTORY WIRING WIRING BY THE INSTALLER 1 = Transformer 2 = F1, fuse 0,2 A 3 = F2, fuse 5 A 4 = VR1, force 5 = VR2, automatic closing 6 = S1, DIP-switch terminals 7 = J2, aerial...
  • Page 10 VR1 - FORCE VR1 trimmer sets the force and the obstacle detection. Turning the trimmer clockwise the force increases while the obstacle detection decreases. If J9 jumper is set right side (ON), the obstacle detection will stop the barrier during closing and will reverse to opening position. Calibrate the obstacle detection force properly, to avoid faults during normal operation.
  • Page 11: Dc Wiring Diagram (24V Dc)

    10. DC WIRING DIAGRAM (24V DC) TIME OPEN_FORCE CLOSE_FORCE LED WORK LED1 LED2 LED3 LED4 OPEN STOP CLOSE LEARN LEARN BRG1 PUSH LED WARNINGS TRANSFORMER MOTOR LIGHTS POWER BATTERY 24V FACTORY WIRING WIRING BY THE INSTALLER 1 = F1, fuse 8 A 2 = VR1, automatic closing 3 = VR2, force in opening 4 = VR3, force in closing...
  • Page 12 TIME VR1- AUTOMATIC CLOSING VR1 trimmer sets the automatic closing time (DIP-switch 2 = ON). The automatic closing time can be adjusted between 1 and 60 seconds. VR2- FORCE IN OPENING OPEN_FORCE VR2 trimmer sets the force and the obstacle detection. Turning the trimmer clockwise the force increases while the obstacle detection decreases.
  • Page 13: Additional Devices

    For automatic opening at car arrival, make an additional jumper between PT and OPN. The RG01 device requires a 24 volt power supply; to fit it with Barry 230V we recommend to use an external power supply, connected to terminals 0V and 24V of the RG01 loop device.
  • Page 14: Start Commands

    11.3 OTHER TYPES OF MASS RECEIVERS If the car stays within the loop area, the barrier remains opened. When the car leaves the loop area, the barrier goes to closing position. The following illustration shows how to connect a loop detector with N.O. contact TERMINAL J5/JP5 LOOP DETECTOR CONTACT N.O.
  • Page 16 Proteco S.r.l. Via Neive, 77 - 12050 CASTAGNITO (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 - info@proteco.net - www.proteco.net...