THERMO-SEALING MACHINE FOR TRAYS
5.2

SUPPLY VOLTAGE

5.2.1
230V SINGLE-FASE POWER SUPPLY
The appliances are provided with a standard 2P+T-10/16A German plug for connection to the electricity mains. Insert the plug in a compatible power
socket supplied by the mains.
ELECTRIC HAZARD! Before making the connection, always check to make sure the
electrical features of the system in the installation area are suitable.
The socket must be earthed and protected by means of a differential magneto-
thermal cut-out switch or a 15 A fuse.
5.3

GENERAL REGULATIONS FOR USE

ELECTRIC HAZARD! First check the voltage indicated on the nameplate to make sure it corresponds to that of your mains
supply. ELECTRICAL SAFETY OF THIS MACHINE IS ONLY ENSURED BY CONNECTING IT CORRECTLY TO AN EFFECTIVE
EARTHING SYSTEM, AS ENVISAGED BY SAFETY STANDARDS. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
DAMAGE CAUSED BY THE ABSENCE OF EARTHING OF THE ELECTRICAL SYSTEM.
ELECTRIC HAZARD! Insert and disconnect the plug in the power socket always with the
machine switched off; pull out the plug, not the cable.
Only qualified personnel are allowed to accede to powered parts.
WARNING! Position the machine on a solid, safe level horizontal work table.
WARNING! The appliance must be positioned in such a manner as to allow access from all sides.
This will also ensure necessary ventilation of the machine.
ATTENTION! Do not touch the sealing plate before and after the
work cycle since it reaches temperatures as high as 140-180°
WARNING! Check the condition of the silicone seals (A) on the tray
holders regularly. Do not use knives or other sharp objects to remove
residua, if present, on the sealing plate: wait for it to cool down
before using blunt tools (see pt. 7.3.2 page 26).
WARNING! Clean the machine thoroughly after use. Clean the stainless
steel parts using special commercial products. Do not use water or steam
jets as this can damage the electrical parts of the appliance (SEE CHAPTER
- CLEANING THE MACHINE).
For all problems (defective working or technical assistance) please
contact our Customer Service.
5.4

CONTROL PANEL

1
1
DIGITAL THERMOSTAT.
2
MAIN SWITCH.
3
FUSES 2.5 A.
4
FUSES 100 m A.
REV. 02 - Cod.: 1500161
1
2
3
4
2
5
5
FUSES 5 A.
6
CORRECT TEMPERATURE INDICATOR LIGHT.
7
TEMPERATURE REGULATION POTENTIOMETER.
8
FUSES 8 A.
A
6
1
23
Operation and maintenance manual / Ed. 06 - 2007
INSTALLATION
NO
OK
7
2
8
2