Check Control Messages - LaCimbali Q10 New Touch Use And Installation

Table of Contents

Advertisement

The check-control messages are divided into two groups:
1. Messages in explicit mode:
2. Messages in code: these appear in the top right-hand corner with the following syntax:i: Exxx
When there are several errors, their representation is timed, passing in succession on the display.
For more details, please consult the technical manual at the "Configuration menu - Defect - Malfunctions".
MESSAGE
POSSIBLE CAUSES: when the message is visualized
Machine cold
1. This message appears on the display after a dispensing key
has been pressed when:
- the services boiler pressure is below the preset operating
pressure;
- the boiler temperature is below 60°C.
When the operating pressure and temperature are reached, the
message will disappear automatically.
2. When the services boiler or the coffee boiler cannot respectively
reach the operating pressure and temperature due to problems,
an error code will appear on the display identifying the defective
component that caused the problem.
Check Boiler
This message is displayed when the machine is switched on and
verifies the filling status of the coffee boiler.
Grounds
This message means that the coffee ground drawer is full.
drawer full
10 more coffee selections (or 5 double dose) may be made
(coffee-based drinks) before the machine is blocked and the
following message is then displayed.
Empy drawer
The machine counts in decreasing order the pre-set maximum
grounds number. This message means that that value run out.
The machine is blocked and no coffees beverages can be de-
livered.
Grounds
This message always appears when the back side of the
drawer
drawer is not in the right position.
removed
Tray extracted
This message (accompanied by the icon on the display) always
appears when the tray is not positioned properly.
Boiler filling
This message is displayed when the machine is filling the
boiler
Service
This message is displayed when the machine requires the peri-
needed
odic maintenance intervention. In order to eliminate temporary the
message, keep pressed RES key for approximately 8 seconds.
The message will reappears in the successive relighting of the
machine with the main switch.
14.

Check Control Messages

they position on the last line at the bottom of the Display (5). They are cancelled on each
new cycle and then appear again if the cause that generated them returns
Messages in explicit mode
77
where:
· E indicates an error;
· xxx rappresents the error code of the unit.
VERIFICATIONS
2. Consult the technical manual and refer to the
specific error code which will be flashed on the
display to solve the problem
Worker has not intervened.
Empty the drawer to reset the counter or wait
until when the machine will display the mes-
sage 'empty drawer'.
Consult the technical manual to program the
number of grounds to the attainment of which
the message will be visualized.
Remove the coffee grounds drawer.
Empty the drawer and replace it in the cor-
rect position. Close the panel. During this
operation the message 'Groun. Draw. Re-
moved' will be displayed.
If this message appears when the drawer is
inserted, check the drawer is correctly posi-
tioned.
Make sure the tray is correctly positioned.
This operation is performed automatically
and requires no action by the user.
This operation does not impede the hot water
delivery.
Contact the authorized technical department.
The message will be displayed until the serv-
ice will be carried out. (Refer to the Techni-
cian's Manual).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents