Session Indicator; Session Status - IBM 3708 End-User Reference

Network conversion unit
Hide thumbs Also See for 3708:
Table of Contents

Advertisement

Session Indicator
Session Status
MYJOB
SSCP
Meaning: The session is connected to the host application or to the 3708
control terminal.
Action:
None
Meaning: The session is connected to the system operator (SSCP control
program).
Action:
None
NNN codes, which can appear in the Session Status field, are described in "NNN
Codes" on page 2-17.
X
CLOCK
Meaning: The system needs time to perform the requested function. The
host application automatically unlocks the keyboard.
Action:
Wait for the condition to clear.
x
PC nnn
Meaning: Program Check. The 3708 detected an SNA data-stream error in
the data from the host.
Action:
See "NNN Codes" on page 2-17 for information.
x
CC nnn
X?+
X -F
Meaning: Communication Check. A condition in the network is preventing
communication with the host.
Action:
See "NNN Codes" on page 2-17 for information.
Meaning: Input not understood.
Action:
Press the Reset key sequence defined for the terminal, check the
screen, and try to enter the data again.
Meaning: Minus Function. The requested function is currently unavailable.
Action:
Press the Reset key sequence defined for the terminal.
XPRTNW
Meaning: Printer Not Working. The printer assigned to the terminal is not
active and no other printers in the class are available. The 3708 discards the
print request.
Action:
Press the Reset key sequence defined for the terminal, activate the
printer, and try the function again.
Chapter 2. Operating in Full-Screen
Mode
2-13

Advertisement

Table of Contents
loading