Servicing Schedule - KELCH KENOVA set line V9 Series Operating Instructions Manual

Table of Contents

Advertisement

5. Maintenance and care

5.4.1 Servicing Schedule

Copy the following servicing schedule and use it as a check list. At the end of the work,
date and sign the filled-in page and save as a work report.
Maintenance Work
Check protective cover
Check guide cover bands for damage
Check the maintenance unit setting
(5 bar)
Inspect air lines and valves for seal
tightness
Clean or replace air filter (PC)
Check the ropes, pulleys and axles of
the counterweight for damage.
Replace damaged components
Check the run-out of the adapter
Check the parallelism of the tapered
holder to the longitudinal guide.
Check the focus adjustment of the
camera
Check the setting of the light source;
readjust if necessary.
Check the rope of the counterweight.
Check the shaft and pulley for wear.
Replace parts if worn
Inspect induction coil for damage
Lack of, or poorly performed, maintenance of the
system can have the following effect:
-
Reduced operational reliability
-
Unnecessary standstills
-
Avoidable repair costs
-
Shortened service life
KENOVA set line V9xx(-S)
Kelch GmbH · Werkstraße 30 · D-71384 Weinstadt-Endersbach · Tel. (+49)7151 20522 0 · Fax (+49)7151 20522 11 · info@kelchgmbh.de
Daily
Weekly Monthly Yearly
X
X
X
X
We recommend that maintenance be carried out by
specialists from Kelch GmbH
Date:
© Kelch GmbH 2014
Servicing Interval
Every 2 years
X
X
X
X
X
X
X
Tel: +49 7151-20522-640
Fax: +49 7151-20522-11
Signature:
Result
OK
not OK
X
Page 31

Advertisement

Table of Contents
loading

Related Products for KELCH KENOVA set line V9 Series

This manual is also suitable for:

Kenova set line v9 s series

Table of Contents