3.5 Pneumatic connection
Figure 7: Maintenance unit with pressure reducer
Connect the pneumatics connector to the compressed air supply (4-6 bar pre-
cleaned, NK 6 hose connector with hose clamp)
Set working pressure to 5 bar
Note!
Note!
3.6 Electrical connection
The device is connected via a country-specific (e.g. Europe/USA) connector to the
mains supply of the workshop.
The ancillary devices (monitor, measurement control unit) are supplied via the pe-
ripherals carrier.
Note!
Note!
Load ratings
Power supply 90 – 260 V, 47 – 60 Hz, grid standard back-up fuse 16 A, Load rat-
ing approx. 2 kW with PC and printer.
Page 20
Kelch GmbH · Werkstraße 30 · D-71384 Weinstadt-Endersbach · Tel. (+49)7151 20522 0 · Fax (+49)7151 20522 11 · info@kelchgmbh.de
The maintenance unit with filter and pressure control valve be-
long to the scope of supply. Do not add any oil!
You will find wiring diagrams and pneumatics diagram in the
documentation folder for your KENOVA set line V9xx(-S)
The main switch on the switch cabinet disconnects the entire
equipment from the power supply.
Wiring diagrams and pneumatics diagram are to be found in the
documentation folder for your KENOVA set line V9xx(-S).
KENOVA set line V9xx(-S)