Bomag BPH 80/65 Operating Instructions, Maintenance Instructions page 48

Compactor
Table of Contents

Advertisement

M a i n t e n a n c e e v e r y y e a r
Maintenance every year
4.19 Changing the fuel filter
Danger
!
When working on the fuel system do not use
open fire, do not smoke, fire hazard! Do not
spill any fuel, do not inhale any fuel fumes.
Caution
!
The change interval of the fuel filter depends
on the cleanliness of the fuel. If necessary the
maintenance must be performed every six
months.
Fig. 57
Open the filler cap on the tank (Fig. 57) .
l
Fig. 58
Place a suitable container under the filter to
l
catch running out fuel (Fig. 58) .
Close the fuel supply line.
l
4 8
Fig. 59
Pull the fuel lines off both sides of the fuel filter
l
and install a new filter (Fig. 59) .
Environment
Dispose of the used filter environmentally.
Caution
!
Ensure strict cleanliness, so that no dirt can
fall into the fuel hose.
The fuel filter must be generally renewed.
l
Mind the flow direction - arrows.
l
Open the fuel supply, if necessary prime with
l
the fuel pump.
Close the filler cap on the tank again.
l
Check fuel filter and lines for leaks after a short
l
test run.
i
Note
The fuel system is automatically bled.
B O M A G