Replacing Srx5400 Services Gateway Spcs; Removing An Srx5400 Services Gateway Spc - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

PIC 3
Online
Slot 1
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 2
Online
For further description of the output from the command, see Junos OS System Basics and Services Command
Reference at www.juniper.net/documentation/.

Replacing SRX5400 Services Gateway SPCs

To replace an SPC, perform the following procedures:

Removing an SRX5400 Services Gateway SPC | 295

1.
Installing an SRX5400 Services Gateway SPC | 297
2.
Removing an SRX5400 Services Gateway SPC
An SPC weighs up to 18.3 lb (8.3 kg). Be prepared to accept its full weight.
To remove an SPC (see
Figure 116 on page
1. Have ready a replacement SPC or blank panel and an antistatic mat for the SPC. Also have ready rubber
safety caps for each SPC you are removing that uses an optical interface.
2. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
3. Power off the services gateway using the command request system power-off.
user@host# request system power-off
NOTE:
Wait until a message appears on the console confirming that the services stopped.
SPU Flow
SRX5k SPC II
SPU Flow
SPU Flow
SPU Flow
SPU Flow
SRX5k IOC II
2x 40GE QSFP+
10x 10GE SFP+
297):
295

Advertisement

Table of Contents
loading

Table of Contents