IBM NetVista N70 Reference page 36

Table of Contents

Advertisement

26
Table 5. POST error codes
POST Error Code
10X
110 Logic Unit memory parity error 1. Memory Module
11X I/O channel parity error
129 Internal cache test error
151 Real Time clock failure
161 Bad CMOS battery
162 Configuration mismatch
163 Clock not updating or invalid
time set
164 POST detected a base memory
or extended memory size mismatch
error or RIMM socket 3 is
populated with a RIMM memory
module
166 Boot Block Check Sum Error
167 Microprocessor installed that is
not supported by the current
POST/BIOS
168 Alert on LAN
error
FRU/Action
Logic Unit
2. Logic Unit
1. Reseat adapters
2. Any adapter
3. Logic Unit
Logic Unit
Logic Unit
1. Check the BIOS Configuration/Setup Utility
Program (see "Appendix C. Using the BIOS
Configuration/Setup Utility program" on
page 43).
2. CMOS Backup Battery
3. Logic Unit
1. Check the BIOS Configuration/Setup Utility
Program (see "Appendix C. Using the BIOS
Configuration/Setup Utility program" on
page 43).
2. Had a device been added, removed, changed
location? If so, suspect that device.
3. Power-on external devices first, then power-on
computer.
4. CMOS Backup Battery on Logic Unit.
5. Logic Unit
1. Time and Date set?
2. CMOS Backup Battery
3. Logic Unit
1. Check the BIOS Configuration/Setup Utility
Program (see "Appendix C. Using the BIOS
Configuration/Setup Utility program" on
page 43). Check System Summary menu for
memory size changes.
2. Memory Module
Logic Unit
Logic Unit
1. Check the BIOS Configuration/Setup Utility
Program (see "Appendix C. Using the BIOS
Configuration/Setup Utility program" on
page 43). Check to see that Ethernet and Alert on
LAN are enabled.
2. Logic Unit