785XNGK, 785XPGK, 785YNGK, 785YPGK
Use with with Valor Models 785X and 785Y Heaters ONLY
This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Main burner elbow injector
1 Set of conversion labels
1 Minimum rate by-pass screw
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
• Manometer, to set pressure, regulator is integral with valve
Specifi cations
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
4004884-02
©2017, Miles Industries Ltd.
Legend G4

Gas Conversion Kit

Installation Instructions

785XN
Natural
Propane
0-4,500 feet*
28,000
14,000
3.5
5.0
10.0
850
51
190
This conversion kit shall be installed by
a qualifi ed service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fi re, explosion or pro-
duction of carbon monoxide may result
causing property damage, personal injury
or loss of life. The qualifi ed service agency
is responsible for the proper installation of
this kit. The installation is not proper and
complete until the operation of the con-
verted appliance is checked as specifi ed in
the manufacturer's instructions supplied
with the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
785XP
785YN
785YP
Natural
Propane
0-4,500 feet*
26,000
28,000
26,000
15,000
14,000
15,000
9.0
3.2
11.0
5.0
14.0
10.0
300
850
30
51
135
190
WARNING
9.5
11.0
14.0
300
30
135

Advertisement

loading

Summary of Contents for Valor Legend G4 785XNGK

  • Page 1: Gas Conversion Kit

    Legend G4 Gas Conversion Kit 785XNGK, 785XPGK, 785YNGK, 785YPGK Use with with Valor Models 785X and 785Y Heaters ONLY Installation Instructions This appliance is certifi ed for use from 0–4500 feet. For WARNING altitudes above 4500 feet, see local codes.
  • Page 2 General Notes Regarding Conversion 3. Remove 8 screws holding module plate to fi rebox base. The conversion may be done before or after the appliance is installed into the cavity. However, the gas must be connected to set the manifold pressure. Prepare the appliance 1.
  • Page 3 5. Refi t the pilot hood by pushing down on it. Ensure 2. Loosen the screws on each side of the shutter and that it snaps into position. slide the shutter as indicated below according to the type of gas used. Replace the minimum rate by-pass screw 1.
  • Page 4 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2017...
  • Page 5 LE PREMIER FOYER À GAZ RADIANT Kit de conversion de gaz 785XNGK, 785XPGK, 785YNGK, 785YPGK Utilisez avec les foyers Valor 785X et 785Y SEULEMENT Directives d’installation Cet appareil est homologué pour utilisation de 0 à AVERTISSEMENT 4 500 pieds. Pour altitudes au-dessus de 4 500 pieds, consultez la règlementation locale.
  • Page 6 À propos de la conversion 3. Enlevez les 8 vis retenant la plaque du brûleur à la boîte de foyer et sortez la plaque du brûleur du foyer. La conversion d’un gaz à l’autre peut être faite avant ou après l’installation de l’appareil dans la cavité. Cependant, le gaz doit être branché...
  • Page 7 Réglez l’obturateur d’air 5. Réinstallez le capuchon de veilleuse en poussant dessus. Assurez-vous qu’il s’enclenche correctement L’obturateur d’air est situé sous le brûleur de céramique (en alignant la fente du capuchon à la clé de la base) vers l’arrière. Remplacez la vis d’indice minimum 1.
  • Page 8 Réinstallez la plateforme de céramique du 2. Fixez un mano-mètre à la connexion de vérifi ca- tion de pression d’admission sur la soupape—voir brûleur l’image ci-dessous. 1. Pour réinstaller le brûleur, insérez-le dans la boîte Dévissez pour vérifi er 3. Allumez l’appareil et de foyer en commençant par le devant, insérant (resserrez après) tournez le contrôle pour...

This manual is also suitable for:

Legend g4 785ypgkLegend g4 785xpgkLegend g4 785yngk