WARNING!
The cylinder valve(s) must be readily accessible for hand operation. A door on the enclosure to
gain access to the cylinder valves is acceptable, provided it is non-locking and can be opened
without the use of tools.
The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiation, a flame barrier, and protection from foreign material, such as
hot drippings. The enclosure cannot be located directly below the grill.
There must be a minimum clearance of 51 mm between the floor of the LP-gas cylinder
enclosure and the ground.
The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected
and the connections inspected and tested outside the cylinder enclosure. Any connections that
can be disturbed when installing the cylinder in the enclosure must be accessible for testing
inside the enclosure.
WARNING!
Built in units are supplied with a drip pan which holds only a minimal amount of
grease. To prevent grease fires, the pan must be cleaned after each use.
WARNING!
Access must be provided to the inside of the enclosure to make gas connections.
DANGER!
Read all instructions carefully before operating the grill. Failure to follow these
instructions exactly could result in a fire causing serious injury or death. The entire installation
must be leak tested before operating the grill.