Delivery And Handling; Transport; Assembly - Nibe F1155 Installer Manual

Ground source heat pump
Hide thumbs Also See for F1155:
Table of Contents

Advertisement

2 Delivery and handling

Transport

F1155 should be transported and stored vertically in a
dry place. When being moved into a building, F1155
may be leant back 45 °.
NOTE
The product can be tail heavy!
If the cooling module is pulled out and transported
upright, F1155 can be transported on its back.
Remove the outer panels in order to protect them when
moving in confined spaces inside buildings.
Pulling out the cooling module
To simplify transport and service, the heat pump can
15 - 40 mm
be separated by pulling the cooling module out from
the cabinet.
See page 54 for instructions about the separation.

Assembly

Position F1155 on a firm base that can take the
weight, preferably on a concrete floor or foundation.
Use the product's adjustable feet to obtain a horizont-
al and stable set-up.
30 - 50 mm
The area where F1155 is located must be equipped
with floor drainage.
Install with its back to an outside wall, ideally in a
room where noise does not matter, in order to elim-
inate noise problems. If this is not possible, avoid
placing it against a wall behind a bedroom or other
room where noise may be a problem.
30 - 50 mm
8
Chapter 2 |
Delivery and handling
Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
Installation area
Leave a free space of 800 mm in front of the product.
Approx. 50 mm free space is required on each side, to
remove the side panels. The panels do not need to be
removed during service, all service on F1155 can be
carried out from the front. Leave space between the
heat pump and the wall behind (and any routing of
supply cables and pipes), to reduce the risk of any
transmission of vibrations.
0
R
*
(50)
* A normal installation needs 300 - 400 mm (any side) for connec-
tion equipment, i.e. level vessel, valves and electrical equipment.
*
(50)
800
NIBE™ F1155