Energy class circ-pump
Max system pressure heating medium
Min system pressure heating medium
Nominal flow (50 Hz)
Max external avail. press at nom flow
Max/Min heating medium temp
Pipe connections
Brine ext diam. CU pipe
Heating medium ext diam. CU pipes
Connection, hot water heater ext diam
Dimensions and weight
Width
Depth
Height
Required ceiling height
Weight complete heat pump
Weight only cooling module
Part number, 1x230V
Part number, 3x230V, with energy meter
Part number, 3x400V, with energy meter
Part number, 3x400V
1)
Reported efficiency for the system takes the product's temperature regulator into account.
2)
With feet removed the height is approx. 1650 mm for F1155.
66
Chapter 12 |
Technical data
2)
F1155-6
low energy
MPa
0.45 (4.5 bar)
MPa
0.05 (0.5 bar)
l/s
0.08
kPa
69
°C
see diagram
mm
mm
22
mm
22
mm
mm
mm
mm
kg
150
kg
90
065 277
065 315
065 275
065 294
F1155-16
0.22
71
28
28
28
600
620
1500
1670
185
125
065 260
065 295