Electrical Panel - Chicago Pneumatic CPVS 20 Product Description

Hide thumbs Also See for CPVS 20:
Table of Contents

Advertisement

including but not limited to: impact separation, gravitational separation and
centripetal separation. The receiver tank collects and recycles the lubricant for
distribution throughout the fluid circuit. Lubricant carryover with new components
is 3ppm.
9. Integrated air/oil cooling blocks of industrial-grade, treated aluminum with finned
pack for the cooling of application air and lubricating oil before injection into the
compression chamber.
10. Filtering panel for pre-filtration of all the air incoming in the machine.
11. Full cabinet enclosure which is aesthetically pleasing, primed and powder-coated
with UV resistant epoxy paint to a minimum of 2 mils. Cabinet is formed from
varnished steel sheet and lined internally with acoustic insulating material.
12. VACON variable speed drive
x Integrated line reactor to smooth voltage fluctuations
x Allows continuous duty operation with turndown as low as 20% of full load
capacity while maintaining a pressure band of +/- 2 psig
x Provides soft start capability
o Reduces inrush currents
o Lowers motor power consumption

ELECTRICAL PANEL

- Electrical control panel in a metallic enclosure with keyed entry in compliance with
the safety standards in force featuring:
x NEMA 1 electromechanical protection
x Automatic soft start operation
x Thermal protection for the electric motor
x Single-phase safety transformer with protection upstream and downstream by
means of circuit breakers
x Power fail circuitry and ES3000 microprocessor
- Disconnecting switch with two positions:
x At position "0" allows the opening of the control panel
x At position "1" allows the starting of the machine
- Identification label indicating the serial number, the model and the identification
data of the compressor
ES3000 CONTROLLER
The CHICAGO PNEUMATIC CPVS 20-30 is managed by the ES3000, an electronic
control unit programmed for energy saving operation with intelligent shut-down.
- Controls all operations related to the use of the compressor: loading, idling, stop
and restart of the compressor
- Performs the control and the regulation of the machine
CPVS 20-30 Product Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpvs 30

Table of Contents