2-3 Installing rewind spring

B
c
D
STARTER SYSTEM
A
a2
a3
C
c
WARNING
Use of eye protection and safety gloves are
strongly recommended while working on re-
wind spring.
If rewind spring unwinds unexpectedly, follow steps
1) to 4).
1) Wind rewind spring (A) by hand. Then draw
a1
out the end of spring (A) as shown.
2) Wind drawn-out part (a1) to wound part (a2),
keeping wound part tight by hand (B) as shown.
Repeating this procedure several times, wind
rewind spring smaller than the inner diameter of
starter case.
3) Retain rewind spring with a pliers as shown.
Set rewind spring in starter case (C), hooking
the outer hook (a3) to the holder (c) of starter
case (C).
4) Apply small amount lithium based grease to
outside of rewind spring.
NOTE: Rewind spring supplied as spare part is
shipped in temporary retainer (D). Retainer should
be removed when installing.
To install new spring wound in retainer:
1) Align outer hook of spring in retainer (D) with
holder (c) of starter case.
2) Push spring down into the bottom of case,
keeping spring strongly pressed against case.
3) Spring should fall into starter case, and re-
tainer is detached.
PB-2520
EB252
DANGER