2-1 Disassembling starter assembly

B
A
C
D
STARTER SYSTEM
c
G
C
E
1. Remove three bolts (A) and remove starter as-
sembly (B) from unit.
2. Pull out starter rope about 30cm (12in) and hold
rope reel (C) by hand. Loop excess rope in rope
reel notch (c) as shown.
3. Rotate rope reel (C) clockwise to release ten-
sion of rewind spring.
4. Remove screw (D) with washer.
5. Remove rope reel (C) from starter case (E)
slowly to prevent rewind spring (G) from unwind-
ing.
WARNING
Wear eye protection and take care when
removing starter drum. Rewind spring may
unwind suddenly and cause personal injury.