Raster Centering - Barco Data 1209s Installation Manual

Hide thumbs Also See for Data 1209s:
Table of Contents

Advertisement

Raster Centering

The raster must be centered on the CRT faceplate of each tube,
therefore, it is necessary to look into the lenses.
Caution : To avoid eye discomfort while performing these adjust-
ments, reduce the contrast and gradually increase the brightness
level until the raster becomes visible behind the image.
Warning : In order to ensure maximum CRT
longevity and to avoid CRT damage, do not shift
the raster outside the phosphor area of the CRT.
Press ENTER to display the raster on the green CRT.
Look into the green lens and shift the raster with the control stick until
it is centered in the middle of the CRT faceplate.
Press ENTER to activate the raster on the Red CRT faceplate.
Shift the Red raster with the control stick until the raster is centered
on the CRT faceplate.
Press ENTER to activate the raster on the Blue CRT faceplate.
Shift the Blue raster with the joy stick until the raster is centered on
the CRT faceplate.
Press ENTER to continue with the CRT projection angle adjustment.
Press EXIT to return to Optical focusing.
Press ADJUST to return to Operational mode.
5975718 BARCODATA 1209s 050698
All manuals and user guides at all-guides.com
Installation adjustment mode
RASTER CENTERING
CONTRAST LEVEL IS REDUCED
AND BRIGHTNESS INCREASED
TO MAKE THE RASTER
VISIBLE ON THE FACE PLATE
OF EACH CRT.
USE THE ARROW KEYS
TO CENTER THE RASTER
ON THE GREEN, RED AND
BLUE CRT RESPECTIVELY
<ENTER> to continue
<EXIT> to return
forbidden area
phosphor border
234
p‚……rp‡Ã…h†‡r…†v‡v‚
…‚tÃ…h†‡r…†v‡v‚
projected raster
crt faceplate border
233
8-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents