Connection
5.2 Electrical connection
5.2.6

Motors with DRIVE-CLiQ interface

NOTICE
Damage to components that are sensitive to electrostatic discharge
The DRIVE-CLiQ interface has direct contact to components that can be damaged/
destroyed by electrostatic discharge (ESDS). Encoder systems and temperature sensors
are components that can be destroyed by electrostatic discharge (ESD).
Components that are sensitive to electrostatic discharge can be damaged if you touch the
connections with your hands or with electrostatically charged tools.
• Carefully observe the information in Chapter "Handling electrostatic sensitive devices
Motors designed for SINAMICS drive systems are equipped with an internal Sensor Module,
which contains an encoder and temperature evaluation system as well as an electronic
rating plate. The Sensor Module is mounted instead of the signal connector and is equipped
with a 10-pin RJ45plus socket. This is known as a DRIVE-CLiQ interface. The pin
assignment is independent of the motor-internal encoder. The Sensor Module can be rotated
through approx. 180°. The typical torsional torque is between 4 and 8 Nm. The Sensor
Module must only be rotated by hand. The use of pipe wrenches, hammers etc. is not
permitted.
Figure 5-10
The signal connection between the motor and Motor Module is established by means of a
MOTION-CONNECT DRIVE-CLiQ cable. The MOTION-CONNECT DRIVE-CLiQ cable
connector must be inserted far enough so that the catch springs engage.
94
(ESD)".
Motor with DRIVE-CLiQ interface (example)
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f