5.2.5

Electrical connection data

Table 5- 2
1PH8 motors, shaft height 80
Terminal
Cable entry
box type
(power)
gk803
1 x M25 x 1.5
gk806
1 x M25 x 1.5
Thread M16 x 1.5 arranged with 90° to signal connection; thread only for options A12, A25 and encoder version A
1)
(without encoder)
Depending on design of metric cable gland
2)
Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52, routing type E
3)
Table 5- 3
1PH8 motors, shaft height 100
Terminal
Cable entry
box type
(power)
gk813
1 x M32 x 1.5
gk823
1 x M32 x 1.5
gk826
1 x M32 x 1.5
Thread M16 x 1.5 arranged with 90° to signal connection; thread only for options A12, A25 and encoder version A
1)
(without encoder)
Depending on design of metric cable gland
2)
Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52, routing type E
3)
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f
Cable entry
Max. external
(external signals)
cable diameter
1 x M16 x 1.5
20 mm
1)
1 x M16 x 1.5
20 mm
1)
Cable entry
Max. external
(external signals)
cable diameter
1 x M16 x 1.5
24.2 mm
1)
1 x M16 x 1.5
24.2 mm
1)
1 x M16 x 1.5
24.2 mm
1)
Number of main
Max. cross-
terminals
section per
2)
terminal
Phases: 3 x M5
1 x 10 mm
Grounding: 2 x M5
Phases: 6 x M5
1 x 10 mm
Grounding: 2 x M5
Number of main
Max. cross-
terminals
section per
2)
terminal
Phases: 3 x M5
1 x 16 mm
Grounding: 2 x M5
Phases: 3 x M5
1 x 16 mm
Grounding: 2 x M5
Phases: 6 x M5
1 x 10 mm
Grounding: 2 x M5
Connection
5.2 Electrical connection
Max. cur-
rent per
terminal
3)
52 A
2
52 A
2
Max. cur-
rent per
terminal
3)
70 A
2
70 A
2
52 A
2
93