6.2.5

Motors with DRIVE-CLiQ interface

Motors designed for SINAMICS drive systems are equipped with an internal Sensor Module,
which contains an encoder and temperature evaluation system as well as an electronic
rating plate. The Sensor Module is installed in place of the signal connector and is equipped
with a 10-pin RJ45plus socket, which is the DRIVE-CLiQ interface. The pin assignment is
independent of the motor-internal encoder.
NOTICE
The Sensor Module is in direct contact with electrostatic sensitive devices. Steps must be
taken to ensure that operators cannot touch the connections either with their hands or with
tools that could be electrostatically charged.
Figure 6-5
The signal connection between the motor and Motor Module is established by means of a
MOTION-CONNECT DRIVE-CLiQ cable. The DRIVE-CLiQ cable connector must be
inserted far enough so that the catch springs engage.
Figure 6-6
1FT7 synchronous motors
Operating Instructions, 04/2010, 610.40075.40b
Motor with DRIVE-CLiQ interface (example)
Encoder interface with DRIVE-CLiQ
Connection
6.2 Electrical connection