Connection
5.2 Electrical connection
Current-carrying capacity for power and signal cables
The current-carrying capacity of PVC/PUR-insulated copper cables is specified in
EN 60204-1.
5.2.2

Circuit diagram

The circuit diagram contains information about wiring and connecting the motor winding. The
circuit diagram can be found on the lid of the terminal box.
Figure 5-1
NOTICE
Cable damage caused by inappropriately changing the cable outlet direction
You will damage connecting cables if you inappropriately change the cable outlet direction.
• The direction of the cable outlet must not be changed as this invalidates warranty
5.2.3
Terminal box
● Assign the terminals in the terminal box as shown in the diagrams "Terminal box: 3-pole"
and "Terminal box: 6-pole".
● Connect the protective conductor.
● Use cable lugs to DIN 46234.
● Do not remove the insulation strips.
● Screw the terminal box cover on again (tightening torque 5 Nm).
88
Circuit diagram
claims.
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f