Burner Description - Riello Gulliver BG1 Installation, Use And Maintenance Instructions

Light oil burners
Table of Contents

Advertisement

Available languages

Available languages

1.

BURNER DESCRIPTION

One stage light oil burner with low pollutant emissions (Nitric Oxide NOx, Carbon monoxide CO and unburnt
Hydrocarbons).
The burner has a device (compensator) which is integral with the air damper that sets the air output.
This device keeps the oxigen level as necessary for the combustion despite any changing of the room tempe-
rature. The dimension of the boiler's combustion chamber must respond to specific values, in order to gua-
rantee a combustion with the lowest polluting emissions rate. The RIELLO Technical Service Personnel will
be glad to give you all the imformation for a correct matching of this burner to the boiler.
Burner with CE marking in conformity with EEC directives: EMC 89/336/EEC - 2004/108/EC, Low Voltage
73/23/EEC - 2006/95/EC, Machines 98/37/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP X0D (IP 40) as EN 60529.
The burner is approved for intermittent operation as per standard EN 267.
CE Certification No.: 0036 0264/99 (371T1) – 0036 0265/99 (372T1) – 0036 0266/99 (373T1) –
0036 0267/99 (387T1), as 92/42/CEE.
6
1 – Oil pump
2 – Air damper adjustment assembly
3 – Nozzle holder assembly
4 – Control-box
1.1
BURNER EQUIPMENT
Flange with insulating gasket . . . . . No. 1
Screw and nuts for flange . . . . . . . No. 1
Remote reset connection . . . . . . . . No. 1
1.2
ACCESSORIES
SOFTWARE DIAGNOSTIC KIT
A special kit is available that, by an optical link to a PC, shows the burner life together with operating hours,
type and number of failures, serial number, etc
To visualise the diagnostics proceed as follows:
Connect the kit supplied separately to the control box socket.
Reading of the information begins when the software programme included in the kit starts.
REMOTE RESET KIT
The burner has a remote reset kit (RS) consisting of a connection and a push-button operating at a dis-
tance of 20 metres max.
In order to install it remove the protective lock-out installed at the factory and insert the lock-out supplied
with the burner (see electrical diagram on page 6).
3399
3
D8004
Fig. 1
Screw and nuts for flange to be fixed to boiler . . . . . .No. 4
Flexible oil pipes with nipples . . . . . . . . . . . . . . . . . . .No. 2
5
4
1
5 – Reset button with lock-out lamp
6 – Flame detector
7 – Temperature probe of the compensator
2
GB
2
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gulliver bg2Gulliver bg4Gulliver bg3

Table of Contents