Parameter Setting; 9�1 Parameter Setting In General - IFM efector300 SD0523 Operating Instructions Manual

Compressed air meter
Table of Contents

Advertisement

9 Parameter setting

During parameter setting the unit remains in the operating mode� It continues to
monitor with the existing parameters until the parameter setting has been com-
pleted�
9.1 Parameter setting in general
3 steps must be taken for each parameter setting:
1
Select the parameter
► Press [Mode/Enter] until the re-
quested parameter is displayed�
2
Set the parameter value
► Press and hold [Set]�
> Current setting value of the param-
eter flashes for 5 s�
> After 5 s: setting value is changed:
incrementally by pressing once or
scrolling by holding pressed�
Numerical values are incremented continuously� To reduce the value: let the display
move to the maximum setting value� Then the cycle starts again at the minimum
setting value�
3
Confirm the parameter value
► Briefly press [Mode/Enter]�
> The parameter is displayed again�
The new setting value is saved�
Set other parameters
► Start again with step 1�
Finish parameter setting
► Press [Mode/Enter] several times until the current measured value is displayed or wait
for 15 s�
> The unit returns to the operating mode�
18
Mode/EnterSet
Mode/EnterSet
Mode/EnterSet

Advertisement

Table of Contents
loading

Table of Contents