Judo PROFIMAT JPF-A Series Installation And Operating Instructions Manual

Judo PROFIMAT JPF-A Series Installation And Operating Instructions Manual

Automatic backwash protective filter

Advertisement

Installation and operating instructions
Installation and operating instructions
JUDO PROFIMAT ¾" - 4"
JUDO PROFIMAT ¾" - 4"
Model JPF-A
Model JPF-A
Automatic backwash protective filter
Automatic backwash protective filter
Valid for: Canada
Valid for: Canada
Indoor use only
Indoor use only
US
US
C
C
Read before use and store!
Read before use and store!

Advertisement

Table of Contents
loading

Summary of Contents for Judo PROFIMAT JPF-A Series

  • Page 1 Installation and operating instructions Installation and operating instructions JUDO PROFIMAT ¾" - 4" JUDO PROFIMAT ¾" - 4" Model JPF-A Model JPF-A Automatic backwash protective filter Automatic backwash protective filter Valid for: Canada Valid for: Canada Indoor use only Indoor use only...
  • Page 2 Postfach 380 shown us by purchasing this product. D-71351 Winnenden You have purchased a state-of-the-art device. It has been carefully checked Email: info@judo.eu • judo.eu prior to delivery. Nevertheless, if difficulties occur, Office address: please contact the closest customer service (see chapter Customer service).
  • Page 3: Table Of Contents

    Potential-free input......18 Potential-free message....19 Fault..........21 Servicing........22 Cleaning........22 Warranty and maintenance... 22 Technical data......23 Versions........25 Installation dimensions....26 Accessories........27 Circuit diagram for device con- trol..........28 Spare parts........30 1701649 • 2019/04 JUDO JPF-A...
  • Page 4: Sion Interference Statement

    1 this device may not cause harmful inter- ference, and 2 this device must accept any interference received, including interference that may cause undesired operation. JUDO JPF-A 1701649 • 2019/04...
  • Page 5: Safety Instructions

    Risk of water damage or damage The water pressure must not fall below 22 to property psi / 150 kPa as otherwise backwashing can be impaired! The device may only be installed by qualified technical personnel. 1701649 • 2019/04 JUDO JPF-A...
  • Page 6 (see Figure 4). • Store the device in a frost-free place Prior to plugging in the device, ensure to prevent damage caused by freez- that the wastewater connection is func- ing water and leakage. tional. JUDO JPF-A 1701649 • 2019/04...
  • Page 7: Symbols Used

    • Type label Scope of supply • Cleaning information • Automatic backwash protective filter, must be observed and maintained in legible pre-assembled condition. • Built-in rotary flange (for JPF-A ¾" - 2") • Installation and operating instructions 1701649 • 2019/04 JUDO JPF-A...
  • Page 8: Function Description

    Fig. 2: JPF-A 1½" - 2" Automatic control Automatic control Differential pressure switch (only Differential pressure switch (only for „ATP“- models) for „ATP“- models) Filter bowl Filter bowl Rotary flange Rotary flange Wastewater connection Wastewater connection JUDO JPF-A 1701649 • 2019/04...
  • Page 9: Materials Used

    • DIN 19628 safety. • DIN 50930-6 All materials are hygienically and physi- ologically harmless and fulfill the require- ments and directives of the Umweltbunde- samt (UBA). Plastics fulfil the requirements of DIN EN 16421. 1701649 • 2019/04 JUDO JPF-A...
  • Page 10: Installation

    For the installation of the device to and including breaks can result. in domestic water piping, only use the supplied built-in rotary flange The built-in rotary flange serves as a con- (see chapter 4.2). necting element between the domestic JUDO JPF-A 1701649 • 2019/04...
  • Page 11: Draining Of The Backwash

    4 Nm for the pipe connection range ¾" - 1¼" / about 10 Nm for the pipe connection range 1½" - 2") so that the seal is effective and the device is not damaged or strained! 1701649 • 2019/04 JUDO JPF-A...
  • Page 12 Installation 4.4.1 Drainage options for the backwash water JPF-A ¾" - 1¼" JPF-A 1½" - 2" JUDO JPF-A 1701649 • 2019/04...
  • Page 13: Commissioning

    After backwashing, the device is vented 1. Open the upstream shut-off valve to fill and ready for operation. the device with water. The device is now under mains pressure. 2. Plug the power supply unit in. 1701649 • 2019/04 JUDO JPF-A...
  • Page 14: Operation

    • Red flashing light: The device is not ready for operation (see Chapter 7). Manual activation • Press manual button: Backwashing is triggered. Maintenance indication • All three LED flash at the same time (see Chapter 8.2). JUDO JPF-A 1701649 • 2019/04...
  • Page 15 The factory setting is for a cleaning interval of one week. Hours Hours Hours Week Month Risk of electric shock! ELECTRO_NO_HEADER Disconnect the power supply unit from the socket. DIP switch S1 3. Place the cover back on and bolt. 1701649 • 2019/04 JUDO JPF-A...
  • Page 16 5.2.4 Backwashing via differential increased wear and backwashing water consumption. pressure control (ATP version only) Mode of operation of the differential pressure switch The impurities filtered off on the filter fab- ric cause an increased differential pressure JUDO JPF-A 1701649 • 2019/04...
  • Page 17: Conversions, Changes

    This ing/home. reduces the mains voltage for 1701649 • 2019/04 JUDO JPF-A...
  • Page 18: Temporary Removal Of The Device

    DIP switch for setting the backwash mode for remote control. Setting the potential-free input WARNING The power supply unit must be connected to make the electrical installation and to adjust the DIP switch. JUDO JPF-A 1701649 • 2019/04...
  • Page 19: Potential-Free Message

    Continuous signal tone until the switch position is cor- rected. Setting the Potential-free input Potential-free message The device has an output for transferring backwashing and fault indication messages potential-free to a peripheral. Fig. 9: Relay contact assignments 1701649 • 2019/04 JUDO JPF-A...
  • Page 20 If there is a fault indication, the relay 1 switches to “zero-current or fault” state. When a backwash is started, relay 2 switches to the "backwashing" state. After a backwash, relay 2 switches to the "no backwashing" state. JUDO JPF-A 1701649 • 2019/04...
  • Page 21: Fault

    Filter bowl Filter bowl was • If water escapes, close shut-off valves. Have the becomes exposed to high filter bowl replaced immediately. clouded. temperatures or solvents. Hairline cracks on the filter bowl. Troubleshooting 1701649 • 2019/04 JUDO JPF-A...
  • Page 22: Servicing

    (see chapter 5.2). The DIN EN 13443-1 pre- scribes that the backwashing must take place every six months. JUDO however recommends to comply with the information in chapter 5.2.1 Backwashing interval. To ensure the process operates success-...
  • Page 23: Technical Data

    Technical data Technical data Automatic backwash protective filter JUDO PROFIMAT ¾" - 4" JPF-A ¾" - 4" The water to be filtered must be of drinking water quality. Information JPF-A ¾" JPF-A 1" JPF-A 1¼" JPF-A 1½" JPF-A 2" about: Pipe connection ¾"...
  • Page 24 1) Applies to a fully opened backwashing valve and 30 - 44 psi (200 - 300 kPa) mains pressure. 2) Standard mesh size Available special sieve mesh sizes: 30 µm / 0.03 mm, 320 µm / 0.32 mm and 500 µm / 0.5 mm (for industrial use) JUDO JPF-A 1701649 • 2019/04...
  • Page 25: Versions

    JPF-ATP 1½" • • 8020243 1½ inch JPF-ATP 2" • • 8020274 2 inch JPF-ATP 2½" • • 8025029 2½ inch JPF-ATP 3" • • 8020210 3 inch JPF-ATP 4" • • 8020211 4 inch 1701649 • 2019/04 JUDO JPF-A...
  • Page 26: Installation Dimensions

    D Height below the pipe middle E Installation depth up to the pipe middle F Waste water connection up to the pipe middle G Waste water nominal diameter G1 Waste water nominal diameter (alternative) Sewer connection necessary JUDO JPF-A 1701649 • 2019/04...
  • Page 27: Accessories

    JPF-A 1½" - 2" ° Safety block JSB (Best.-Nr. 8105001) for retrofitting the filter with pressure reducer, non-return valve, inlet and outlet pressure manometer 1701649 • 2019/04 JUDO JPF-A...
  • Page 28: Circuit Diagram For Device Control

    Technical data Circuit diagram for device control JUDO JPF-A 1701649 • 2019/04...
  • Page 29 Technical data Circuit diagram for device control with potential-free relays 1701649 • 2019/04 JUDO JPF-A...
  • Page 30: Spare Parts

    Technical data Spare parts JPF-A ¾" - 1¼" JUDO JPF-A 1701649 • 2019/04...
  • Page 31 Sheet metal screw 3,5×9,5 Top of housing JPF-A ¾" Top of housing JPF-A 1" Top of housing JPF-A 1¼" Cylinder screw M6×40 Flange ring Filter bowl 2021284 152 List of spare parts JPF-A ¾" - 1¼" 1701649 • 2019/04 JUDO JPF-A...
  • Page 32 1) AU = Accounting unit (items without AU are only available in a set) 2) AU not yet specified at the time of going to press Replacement interval: *** = 3 years **** = 4 years JUDO JPF-A 1701649 • 2019/04...
  • Page 33 Technical data JPF-A 1½" - 2" 1701649 • 2019/04 JUDO JPF-A...
  • Page 34 Sheet metal screw 3,5×9,5 Top of housing 1½" - 2" Top of housing 1½" - 2" special Mesh size Cylinder screw M6×45 Flange ring Filter bowl 2020811 O-ring 15×3,2 List of spare parts JPF-A 1½" - 2" JUDO JPF-A 1701649 • 2019/04...
  • Page 35 1) AU = Accounting unit (items without AU are only available in a set) 2) AU not yet specified at the time of going to press Replacement interval: *** = 3 years*** **** = 4 years 1701649 • 2019/04 JUDO JPF-A...
  • Page 36 Technical data JPF-A 2½" - 4" JUDO JPF-A 1701649 • 2019/04...
  • Page 37 Power supply unit 2021368 VE HE contact sensor red 2½" HE contact sensor red 3" - 4" HE contact sensor yellow 2½" HE contact sensor yellow 3" - 4" List of spare parts JPF-A 2½" - 4" 1701649 • 2019/04 JUDO JPF-A...
  • Page 38 Sieve insert Mesh size 0,10, 3" - 4" O-ring 29,87×1,78 O-ring 100×1,5, 3" - 4" O-ring 113,67×5,33, 2½" O-ring 178×6, 3" - 4" O-ring 12×3, 2½" O-ring 12×3, 3" - 4" List of spare parts JPF-A 2½" - 4" JUDO JPF-A 1701649 • 2019/04...
  • Page 39: Disposal

    2) AU not yet specified at the time of going to press Replacement interval: *** = 3 years **** = 4 years Disposal Respect the locally valid regulations and guidelines when disposing of packaging, used batteries and old appliances. 1701649 • 2019/04 JUDO JPF-A...
  • Page 40: Customer Service

    Customer service Customer service JUDO Water Treatment Inc. 240 Lesmill Road Toronto, ON M3B 2T5 Canada Telephone: (0416) 441-1556 Toll-free (Canada/USA: (866) 451-5836 Fax: (416) 391-4273 e-mail: info@judo-online.com judo-online.com Installed by: All pictorial, dimensional and implementation information correspond to the date of going to press.

This manual is also suitable for:

Profimat jpf-a 3/4"Profimat jpf-a 2"Profimat jpf-a 1 1/2"Profimat jpf-a 2 1/2"Profimat jpf-a 3"Profimat jpf-a 4" ... Show all