Page 1
JUDO PURE@TAP Under-sink water filter Language: English Attention: Carefully read through the instal- lation and operating instructions and safety information before installing and putting the unit into service. These instructions must always be issued to the owner/user. Fig.: JUDO PURE@TAP...
The under-sink water filters may only be used in a technical condition, free from de- fects, in accordance with the instruction, safety-conscious danger-conscious with respect to the operating instructions! Any functional defects are to be removed immediately! JUDO PURE@TAP...
Therefore all the electrical devices / equipment situated in the direct vicinity should be splash-water proof, respectively comply with the statutory re- quirements for wet areas (NEMA type 12 / IP44). JUDO PURE@TAP...
Appropriate mounting place: Concerning its mounting place the under- sink water filter is intended to be installed di- Fig. 3: JUDO PURE@TAP rectly under the sink (see chapter “Modifica- Under sink installation tions / Changes / Spare parts”). The protection towards the drinking water network has to be executed in accordance with the local regulations.
Page 8
– Screw together from the bottom the rub- ber washer (1.3), the locating washer (1.4) and the star washer (1.5) with the hexagon nut (1.6). – Tighten carefully. – Connect the hose adaptor 7/16"-24 UNS (1.7) to the faucet (1.1). – Tighten carefully. JUDO PURE@TAP...
Page 9
The bleed screw must be slightly unscrewed so that the air can escape. Retighten the bleed screw (see fig. 7). It has to be flushed till the clear water will run off. Re-close the faucet. JUDO PURE@TAP...
Page 10
Setting of the filter change indicator: Move the indicator button on the cover to the next filter change point-in-time (filter change every 4 - 6 months at the latest). Bleed screw under the flange cover Fig. 7: Bleed screw JUDO PURE@TAP...
Always observe the chapter “Intended use”! Commissioning Before starting up (initial putting into service or start-up after maintenance work), fill the JUDO PURE@TAP with water and vent! 1 Slowly open the water shut-off valve and the faucet to vent the system. Activated...
4 - 6 months at the latest). 6 Turn the filter housing to the left up to the 15 Hang the JUDO PURE@TAP water filter limit stop and pull it off downward. into the wall holder and connect the hoses and adapters.
Page 14
Service Filter-change indicator Flange cover 5 mm Allen key Bleed screw Built-in rotary flange Used cartridge Micro-filtration Replacement cartridge Micro-filtration Used cartridge Activated carbon Cylinder head screw Profiled flange gasket Filter housing complete Fig. 11: Replacing the cartridges JUDO PURE@TAP...
(see chapter “Replacing the cartridges”) Leaks in the Under-sink water Close the water shut-off valve and inform the fitter or under-sink filter has been the nearest customer service center. water filter. exposed to higher temperatures or solvents. JUDO PURE@TAP...
In the building services sector this is covered by DIN EN 806-5. Fig. 12: Faucet JUDO design Wherever possible, the regular servicing work and supply with consumables and wearing materials, etc. should be carried out by the specialist trade or the factory’s cus-...
(0.53 US gpm) (0.44 GB gpm) 10.1 Type Total capacity of filter MF: 2000 l* cartridge (525 US gal) JUDO PURE@TAP (440 GB gal) Under sink water filter AC: 2000 l* Order no.: 8115029 (525 US gal) (440 GB gal) Effective filter value 0.2 micron...
Spare parts 11. Spare parts 20 19 JUDO PURE@TAP...
Page 19
Spare parts Spare parts list JUDO PURE@TAP Designation (recommended average replace- Item Piece(s) Order no. ment interval for wearing parts [*]) piece Replacement set price acc. to current price ****** 8115025 Cartridges activated carbon / micro-filtration list Spare parts set Flange cover, complete...