Judo PROFI-PLUS Installation And Operating Instructions Manual

Judo PROFI-PLUS Installation And Operating Instructions Manual

Backwash protective filter 3/4" - 2"

Advertisement

Attention:
Carefully read through the instal-
lation and operating instructions
and safety information before
installing and putting the unit into
service.
These instructions must always
be issued to the owner/user.
Installation and
operating instructions
JUDO PROFI-PLUS
Backwash protective filter ¾" - 2"
Valid for: EU countries and Switzerland
Language: English
+
Fig.: JPF
¾" - 1¼"
+
JPF
¾" - 1¼"
Fig.: JPF-QC 1½" - 2"
+
JPF
¾" - 1¼"
JPF-QC 1½" - 2"

Advertisement

Table of Contents
loading

Summary of Contents for Judo PROFI-PLUS

  • Page 1 Installation and operating instructions JUDO PROFI-PLUS Backwash protective filter ¾" - 2" Valid for: EU countries and Switzerland Language: English Attention: Carefully read through the instal- lation and operating instructions and safety information before installing and putting the unit into service.
  • Page 2 Trademarks used in this document are protected and registered trademarks of the respective holder. © JUDO Wasseraufbereitung GmbH 71364 Winnenden Germany All rights reserved. Reprints – even of extracts – is only permitted with special approval. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 3 JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 4: Table Of Contents

    10.1 JPF-QC ¾" - 1¼" ......24 safe and proper work must also be 10.2 JPF-QC 1½" - 2" ......26 observed. 11. Customer service ......28 Therefore, this instruction manual must always be read by the fitter and responsible JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 5: Symbols Used

    DN 20 – Rating plate 1" DN 25 – Cleaning information 1¼" DN 32 must always be observed and kept in a fully 1½" DN 40 legible condition. 2" DN 50 Fig. 1: Built-in rotary flange JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 6: Intended Use

    The use of the device in accordance with the customer’s specifications includes observance of the operating instructions. manufacturer/supplier should consulted prior to any operation of the filter other than in the operational areas stated in these operating instructions. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 7: Water Pressure

    In the event of such cases persons are at risk and may sustain electrical shocks. Therefore any electrical devices/installations situated in the direct vicinity should be splash-water proof or comply with the statutory requirements for wet areas. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 8: Product Information

    KTW guideline of the German Fed- eral Environmental Agency as well as the DVGW working sheet W 270. Metallic mate- rials fulfil the requirements of DIN 50930-6 (Impact on the drinking water quality). JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 9: Installation

    – It is not permitted to install the Backwash protective filter upstream of the water meter! The shipping carton can be slipped over the built-in filter to prevent damage, for instance at construc- tion sites. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 10 In this case, people close to the filter are ex- water escaping. This can in turn cause water posed to a health risk due to the large quan- damage to the house and its installations tities of water. (see fig. 4). JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 11: Discharging The Backwashing Water

    – When the bucket is half-filled the back- washing process must be stopped. Oth- erwise it is possible for the bucket to overflow. Therefore the bucket must be adequately dimensioned and the back- washing should be carried out quickly. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 12 > 100 mm > 100 mm > 100 mm > 100 mm > 200 mm > 200 mm min.15 l min.10 l > 40 mm > 20 mm > 40 mm Fig. 5: Backwashing water discharge options JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 13: Operation

    Insert the two included batteries in the battery compartment. Use 1.5 V Micro batteries. Fig. 6: Functional description • Replace the handwheel lid. • You can test the functionality by pressing the -key in the lid of RESET the handwheel. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 14: Backwashing

    Water inlet the sieve cloth in the fine filter (12) but also b Filtered water the transparent filter hood (6) using a rubber lip on its exterior side. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 15 Unauthorised persons must not operate the filter! Persons who operate the filter must observe the operating instructions. Failure to observe these instructions can result in damage to property and personal injuries. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 16: Modifications / Changes / Spare Parts

    Strictly com- ply with the instructions given in the “Installation” and “Maintenance” chapters. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 17: Stoppages

    The battery is used up. Replace the batteries with does not beep when the new ones! Return used bat- -key is pressed. teries to the collection cen- tres! (only JPF ¾" - 1¼") JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 18: Maintenance

    ATTENTION (see chapter “Safety information dangers due to non-compliance”) To make sure the total interval of two- months is not exceeded, backwash the filter after replacing the batteries. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 19: Warranty And Services

    (see chapter 5.3.1). DIN EN 13443-1 specifies that backwashing must take place at least every six months. However, JUDO recommends to carry out backwashing every two months! In order to achieve an operation success also after the putting into service and over many years, regular inspection and routine servicing of the unit are indispensable.
  • Page 20: Data Sheet

    0.03 mm, 0.32 mm and 0.5 mm are available for technical and industrial use. Filters with special mesh sizes are not sub- ject to tests according to DIN 19632 and for this reason are not allowed to bear the DVGW mark. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 21: Technical Data

    0.3 - 0.8 l/s JPF-QC 2" 10.2 kg 16.0 (22.0) m³/h 0.3 - 0.8 l/s The backwashing volumetric flow given applies to 2 - 3 bar mains pressure and for a com- pletely opened flushing water valve. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 22: Installation Dimensions Jpf ¾" - 1¼

    B = Unit width G = Connection dimension waste water C = Height above pipe centre G1 = Connection dimension waste water D = Height below pipe centre (alternative) E = Depth to pipe centre JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 23: Extent Of Supply

    JPF-QC 1½" - 2": – JUDO safety block JSB (order no. 8105001) For subsequent filter retrofitting to house water stations. Contains a pressure re- ducer, non-return valve, inlet and outlet pressure manometer. JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 24: 10. Spare Parts

    Spare parts 10. Spare parts 10.1 JPF ¾" - 1¼" JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 25 Cylinder screw M6x25 2010199 O-ring 6.5x6 Hose connection 1120310 Cover Filter funnel 1) AU = Accounting unit (Items without AU are only available in a set.) Replacement interval: *** = 3 years, **** = 4 years JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 26: Jpf-Qc ¾" - 1¼

    Spare parts 10.2 JPF-QC 1½" - 2" JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 27 1607117 Hose connection 1607157 Profiled flange gasket Cylinder screw M8x30 1607116 1) AU = Accounting unit (Items without AU are only available in a set.) Replacement interval: *** = 3 years, **** = 4 years JUDO PROFI-PLUS / JUDO PROFI-QC...
  • Page 28: 11. Customer Service

    Postfach 380 • D-71351 Winnenden Tel. +49 (0)7195 / 692-0 e-mail: info@judo.eu • judo.eu JUDO Wasseraufbereitung GmbH • Niederlassung Österreich Zur Schleuse 5 • A-2000 Stockerau Tel. +43 (0)22 66 / 6 40 78 • Fax +43 (0)22 66 / 6 40 79 e-mail: info@judo-online.at •...