Graco Pulse 25D130 Installation And Service page 5

Metered dispense valve oil bar
Table of Contents

Advertisement

5.
Install the metered dispense valve in oil
bar housing by connecting fitting (1) on
metered dispense valve to pipe nipple
(8) in manifold (2) as shown in F
Tighten securely.
NOTE: Do NOT apply thread sealant or
PTFE tape to threads of fitting (1).
1
8
F
. 12
IG
6.
Wrap threads on the long end of nipple
adapter (10) with PTFE tape or thread
sealant as shown in F
F
. 13
IG
3A5573C
. 12.
IG
2
. 13.
IG
7.
Install the end of the nipple adapter (10)
that was wrapped in the PTFE tape or
treated with thread sealant into the
manifold (2) through the hole (b) in the oil
bar mounting plate (24).
10
F
. 14
IG
8.
Connect the swivel elbow (6) and high
flow nozzle (11) to nipple adapter (10) in
the orientation shown in F
securely.
NOTE: Do NOT apply thread sealant or
PTFE tape to threads.
6
F
. 15
IG
9.
Connect fluid distribution lines (c) to
fitting (3).
F
. 16
IG
Installation
24
2
b
. 15. Tighten
IG
10
11
c
3
5

Advertisement