Installation - Graco Pulse 25D130 Installation And Service

Metered dispense valve oil bar
Table of Contents

Advertisement

Installation

Installation
Prepare the Metered Dispense Valve for Installation
1.
Secure the metered dispense valve in a
vise (F
. 1).
IG
F
. 1
IG
2.
Install strainer (9) and fitting (3) in the
inlet (F
. 2). Use wrench to tighten fit-
IG
ting.
NOTE: An o-ring is not required for the
strainer (9) installation. An o-ring is
required and installed on fitting (3).
9
3
F
. 2
IG
3.
Install fitting (1) in the outlet as shown
in F
. 3. Tighten fitting with a wrench.
IG
1
F
. 3
IG
2
4.
Install Graco identification label (7) over
the existing GRACO identification label
in the orientation shown in F
7
F
. 4
IG
5.
Use the Utility Menu to flip the display for
easy viewing when the metered
dispense valve is installed in the Oil Bar.
See the Pulse Metered Dispense Valve
instruction manual for this procedure.
. 4.
IG
3A5573C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pulse 25d121

Table of Contents