Swing motor

When it is powered on,the swing motor turn to position O, to turn off the air outlet vent.
When the unit is turned on, firstly will turn to the largest air outlet vent position D2, then
it will return to positon L and wait.
If in the swing state, the louver will swings between L and D1; When in heat, will swing
between L and D2
When the unit is turned off, will return to position O.
Buzzer
When PCB is powered on or received the signal from the wireless remote control, the buzzer will send out the sound.
Run indicator
When defrosting, the Run and Heat indicator lights will flash, when anti-freezing, the Run and Cool indicator lights
will flash.
Auto button
When PCB is turned on, press this button to turn off the unit. When PCB is turned off, press
this button, it will run in AUTO mode.
TIMER button
When use wireless remote control to turn on, turn off the unit, the interval of setting is 0.5h, the setting range of
turning on, turning off is 0.5-24hours.
Auto fan control (Model Y502 wireless remote control)
According to the changes of ambient temp., it will decide the fan speed:Low,Med, High. In DRY and AUTO fan mode,
it will run in Low.
SLEEP
In COOL or DRY mode, after setting the SLEEP for 1hour, Tset will rise up 1℃; 2hours later, Tset will rise up 2℃.
W ithin 2 hours, it has been risen up 2℃ totally, and the unit will keep running in this temperature.
When in HEAT mode, after setting the sleep for 1 hour, Tset will be declined 1℃; 2hours later,
Tset will be declined 2℃.Within 2hours, it has been declined 2℃ totally, and the unit will keep running in this
temperature.
In AUTO mode, the setting temp. of sleep function will not change .
Compelling defrosting function
When send the compelling defrosting order by wireless remote control, PCB will enter into DEFROSTING mode.
Bird Dual-Split type
Bird Dual-Split Type