INSTALLATION
The safety valve kit :
Primary circuit safety valve at the back of the water heater
FR
NL
ES
IT
DE
The expansion vessel kit (mandatory accessory):
A primary circuit expansion vessel MUST BE installed at the back of the water heater.
PL
RU
en
38

RECOMMENDATIONS FOR DHW CONNECTIONS

Essential recommendations for safety
The hot water output may reach temperatures in excess of 60°C, which can cause
scalding! It is therefore necessary to install a thermostatic mixing valve after the
appliance.
The system must be fitted with an approved safety group, comprised of a 7 bar
safety valve, a check valve and a shut-off valve.*
Essential recommendations for the correct operation of the appliance
Flush the system before connecting the domestic hot water circuit. Refer to the
installation instructions.
Make sure to install a pressure reducing valve set at 4.5 bar if the mains supply
pressure is in excess of 6 bar.
It is recommended to install an expansion vessel in the DHW circuit to prevent the safety
valve from opening constantly and reduce the water hammer effect in the system.
If the appliance is used as a domestic hot water preparation tank, a primary
Make sure to install the expansion vessel kit (accessory) provided for the Water
expansion vessel adapted to the boiler power/size and to the type of system must
heater.
be fitted in the heating circuit (if there is no built-in expansion vessel, or if the built-
in expansion vessel size is not sufficient).
Typical installation with internal DHW tank
Description
1. Isolating valve
2. Pressure reducing valve
3. Check valve
4. DHW expansion vessel
5. Safety valve
6. Drain valve
7. Grounding
8. Draw-off tap
9. Thermostatic mixing valve
Cold water
Hot water
*
For UK specific requirements for the discharge from safety valves, refer to «G3 Require-
ments and Guidance - UK Only» on page 34.
WaterMaster 25 - 35 - 45 - 70 - 85 - 120 : A1006482 - 664Y7300 • D
8
9
1
1 2 3
4
5
6
7