CONNECTION TO THE DHW CIRCUIT
1.
Filling valve
2.
Pressure reducing valve (set at 4.5 bar)
3.
Check valve
4.
DHW expansion vessel
5.
Safety valve (set at 7 bar)
6.
Drain valve
7.
Draw-off tap
8.
Pressure gauge
9.
Grounding
10. Stop valve
11.
Thermostatic mixing valve
12. Air vent
Cold water
Hot water
1. Thermostatic mixing valve
2. Mixed water outlet - Ø 3/4" [M]
3. DHW expansion vessel connection - Ø 3/4" [M]
4. Safety unit (7 bar)
5. Outlet hot water tank - Ø 3/4" [F]
6. Inlet cold water tank - Ø 3/4" [F]
7. Cold water inlet - Ø 3/4" [M]
8. Drain connection - Ø 1" [M]
The drain connection
avoid hot water projections on the top cover of the tank.
EN
Installation
Domestic hot water kit (option)
must be connected to the sewer system to
8
SLE - SLE Plus: A1007847 - 661Y2100 • D