Download Print this page

Hydraulic Characteristics; Dhw Performance; Maximum Operating Conditions - ACV WaterMaster 25 Installation, Operation And Maintenance Instructions For The Installer And The User

Hide thumbs Also See for WaterMaster 25:

Advertisement

EN
TECHNICAL CHARACTERISTICS

HYDRAULIC CHARACTERISTICS

FR
Main Characteristics
Capacity (primary)
Capacity (DHW)
NL
Water pressure drop (primary circuit)
(Δt = 20 K)
ES

DHW PERFORMANCE

Domestic hot water performance* (cold drink water at 10°C)
Operating conditions at 80°C
IT
40 °C [∆T = 30 K]
Constant flow at
45 °C [∆T = 35 K]
60 °C [∆T = 50 K]
40 °C [∆T = 30 K]
Peak flow at
45 °C [∆T = 35 K]
DE
60 °C [∆T = 50 K]
40 °C [∆T = 30 K]
Peak flow 1st hour at
45 °C [∆T = 35 K]
60 °C [∆T = 50 K]
Reheat time from 10°C to 80°C
PL
DHW efficiency at T = 30 K
Domestic hot water performance* (cold drink water at 10°C)
Operating conditions at 80°C
RU
40 °C [∆T = 30 K]
Constant flow at
45 °C [∆T = 35 K]
60 °C [∆T = 50 K]
40 °C [∆T = 30 K]
Peak flow at
45 °C [∆T = 35 K]
60 °C [∆T = 50 K]
40 °C [∆T = 30 K]
Peak flow 1st hour at
45 °C [∆T = 35 K]
60 °C [∆T = 50 K]
Reheat time from 10°C to 80°C
DHW efficiency at T = 30 K
en
32
WaterMaster
25
35
45
70
L
100
100
100
125
L
96
96
96
190
mbar
3
6
10
9
WM 25
WM 35
L/h
788
1,104
L/h
676
946
L/h
473
662
L/10'
361
408
L/10'
301
339
L/10'
183
197
L/60'
1,018
1,328
L/60'
865
1,127
L/60'
577
749
min.
35
26
%
105.4
105.4
WM 70
WM 85
L/h
2,087
2,534
L/h
1,789
2,172
L/h
1,252
1,520
L/10'
716
783
L/10'
592
646
L/10'
348
371
L/60'
2,455
2,895
L/60'
2,083
2,456
L/60'
1,391
1,638
min.
27
24
%
103.9
103.9

MAXIMUM OPERATING CONDITIONS

Maximum Service Pressure (tank full of water) *
- Primary circuit : .................................................................................................................... 3 bar
85
120
- DHW circuit : ...................................................................................................................... 8.6 bar
125
125
190
190
Maximum Operating Temperatures
- Maximum temperature (primary) : ...............................................................................87°C
14
27
- Maximum temperature (DHW) : .................................................................................... 75°C
Water Quality
See "Recommendations for the Prevention of Corrosion and Scaling in Heating Systems" on the following
page.
WM 45
1,390
1,192
820
471
373
320
1,610
1,366
894
23
103.1
WM 120
3,402
2,928
1,754
900
676
440
3,620
3,098
1,847
23
102.2
*
The hydraulics of the water heater have been tested according to EN 89:2015, and the water heater is classified as a pressure class 3
appliance.
WaterMaster 25 - 35 - 45 - 70 - 85 - 120 : A1006482 - 664Y7300 • D

Hide quick links:

Advertisement

loading