Operation
IQ VVC-208 Control
SYSTEM PROGRAMMING (continued)
KEY PRESS
6
Set Temperature Mode
7
Program Setback Time
8
Program Setback Temperature
9
Set Hold Time
10
Set Hold Temperature
11
Set Hold Done
12
Set Hold Fan Speed
DISPLAY
TEMPERATURE
F = FAHRENHEIT or
C = CELSIUS
SETBACK TIME
HH:MM
SETBACK TEMP
xxx
HOLD TIME
HH:MM
HOLD TEMP
xxx
HOLD DONE
(AUTOMATIC, MANUAL)
HOLD FAN SPEED
(HIGH, LOW)
20
ACTION
Press the LEFT or RIGHT arrow
keys to select the method that
all temperatures will be dis-
played in.
Press the "P" key to lock in your
entry
Press the numbered prod-
uct keys to select the time in
HH:MM format for activating
Setback mode.
NOTE: 0:00 is default to disable
Setback.
Press the "P" key to lock in your
entry
Press the numbered product
keys to select the Setback
temperature in the range of
140-300°F.
Press the "P" key to lock in your
entry
Type in the length of hold time
required. The value is in the
range of 00:00 to 99:59.
Press the "P" key to advance to
the next stage or parameter.
Type in the desired Hold tem-
perature. Hold Temperature
Range is 140-210°F
Press the "P" key to advance to
the next stage or parameter.
Press the LEFT or RIGHT arrow
keys to select Hold Done.
Press the "P" key to advance to
the next stage or parameter.
Press the LEFT or RIGHT arrow
keys to select Hold Fan Speed.
Press the "P" key to advance to
the next stage or parameter.