SCK ADDRESS (6647)
KEY PRESS
1
Enter Program Mode
2
Enter Pass Code
3
Set SCK Address
4
Set SCK Node
5
Exit SCK Programming
DISPLAY
ENTER CODE
****
SCK ADDRESS
xx
NETWORK NODES
xx xx xx xx xx
ExIT
23
Operation
IQ VVC-208 Control
ACTION
•
To enter programming mode,
press and hold the "P" key for 3
seconds.
•
Scroll to Programming.
•
Press the "P" key.
•
The display will prompt user to
enter a pass code.
•
Enter pass code 6 6 4 7.
•
Press the "P" key to lock in your
entry.
•
Scroll to SCK Address.
•
Press "P" to advance.
•
Press the LEFT or RIGHT ar-
row keys to scroll through the
SCK address to be used for this
controller. The range is from 1
to 31, or "Auto Assign."
•
Press the "P" key to lock in your
selection.
•
The display will scroll in mar-
quee-style all SCK Nodes cur-
rently in the system. Scrolling
will constantly be updated.
•
Press the "P" key to advance.
•
Scroll to Exit.
•
Press the "P" key to return to
idle.