RECIPE PROGRAMMING (continued)
KEY PRESS
9A
Set Stage 1 Fan ON
9B
Set Stage 1 Fan OFF
10
11
Set Alarm 1 Time (Selectable)
12
Set Alarm 1 Name (Selectable)
13
Set Alarm #1
Done Mode (selectable)
14
Setting Alarm 1 Tone
15
STAGE 1 FAN CYCLE
(FULL, HEAT, PULSE)
STAGE 1 FAN OFF
If applicable, repeat steps 5-9 for additional stages.
A total of 9 stages can be programmed.
ALARM 1 TIME
ALARM 1 NAM
ALARM 1 DONE
(AUTOMATIC, MANUAL)
ALARM 1 TONE
SHORT, MEDIUM, LONG,
DOUBLE, LONG/SHORT, NONE
If applicable, repeat Steps 10-13 for additional Action Alarms.
A total of three (3) Action Alarms can be programmed.
DISPLAY
MM:SS
"ACTION"
17
Operation
IQ VVC-208 Control
ACTION
•
Press the LEFT or RIGHT arrow
keys to select the fan cycle.
•
Press the "P" key to advance to
next stage or parameter.
NOTE: THIS SECTION ONLY AP-
PEARS IF "PULSE" IS SE-
LECTED FOR FAN CYCLE.
•
Type in desired fan OFF time.
•
Press the "P" key to advance to
next stage or parameter.
•
Type in Alarm Time for activat-
ing the Action Alarm. Skip Steps
11-14 if the Alarm Time for this
stage is zero.
•
Press the "P" key to advance to
the next stage or parameter.
•
Press the UP or DOWN arrow
keys to scroll through the Alarm
Names, OR start spelling the
desired action alarm name by
pressing the appropriate prod-
uct keys.
•
Press "P" key to lock in the
selection.
•
Press the LEFT or RIGHT arrow
keys to select how the Action
Alarm is to be canceled.
•
Press the "P" key to advance to
next stage or parameter.
•
Press the LEFT or RIGHT arrow
keys to select Alarm Tone.
•
Press the "P" key to advance to
next stage or parameter.