4. FIRE RISK SAFETY

On installation of the thermoheating stove the following safety measures must be observed:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing
components flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with
flammable structure (see Picture 4 A). All of the minimum safety distances are shown on the product data
plate and lower values must not be used.
b) must be no objects or inflammable construction or heat sensitive materials in front of the fireplace door, in the
area of radiation, nearer than 100 cm. This distance can be reduced to 40 cm if a back-ventilated and heat
resistant protection is installed, in front of the entire component to be protected.
c) If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The floors
made of inflammable material, such as moquette, parquet or cork etc., must be replaced by a layer of no-
inflammable material, for instance ceramic, stone, glass or steel etc. (dimensions according to the local
regulations). The platform must project frontally by at least 50 cm and laterally by at least 30 cm beyond the
opening of the loading door (see Picture 4 B).
d) no flammable components (e.g. wall units) must be present above the product.
The thermoheating stove must function exclusively with the ash box inserted. The solid residues of combustion (ash)
must be collected in a fire-resistant hermetic container. The thermoheating stove must never be ignited in the
presence of gaseous emissions or vapours (e.g. glue for linoleum, petrol etc.). Do not deposit inflammable materials
in the vicinity of the thermoheating stove.
Heat energy is released during combustion that leads to a marked heating of the surfaces, the door and the glass of
the fireplace, the door and control handles, the fumes pipe and eventually the font part of the appliance. Avoid contact
with these elements without corresponding protective clothing or without using tools (heat-resistant gloves, control
devices).
Make sure that children are aware of these dangers and keep them away from the fireplace while functioning.
When an incorrect or too humid fuel is used deposits may form (creosote) in the flue with possible catching fire of the
flue itself.

4.1. EMERGENCY PLAN

If a fire occurs in the connection or in the flue:
a) Close the loading door and ash box door.
b) Close the combustion air regulators
c) Out the fire out using carbon dioxide extinguishers (powder CO2)
d) Request the immediate intervention of the fire service
DO NOT PUT THE FIRE OUT USING WATER.
When the flue stops burning, have it checked by a specialist in order to identify any cracks or permeable points.