Step 2: Trim Installation - Signature Hardware EXIRA Installation

Thermostatic shower set

Advertisement

EXIRA THERMOSTATIC SHOWER SET INSTALLATION
4. Once all piping is routed and connections have been
made, use a ½" test plug to perform a water pressure
test. Turn on the main water supply to your home and
water test the installed plumbing. Ensure that there are
no leaks, then shut the water off. Remove the test plug.
Note: Water pressure testing should be performed by
a licensed plumber if you are not familiar with this
procedure.
IMPORTANT: COMPLETE THE CONSTRUCTION OF
YOUR WALL, INCLUDING ANY FINISHED WALL
MATERIALS SUCH AS TILE, BEFORE PROCEEDING
WITH THE REMAINDER OF THE INSTALLATION.
STOP

Step 2: Trim Installation

1. Once the finished wall is complete, remove the
protective sleeves from the valve stems. If the test plug
has not yet been removed, remove that as well.
2. Slide each of the decorative back plates onto the
valve stems. Ensure that the markings located above
each opening on the back plates are facing up.
Exira Thermostatic Shower Installation Instructions