Installing the lock trim
9. Connect ribbon cable, motor cable, and power wire to the PCB. See Fig. 6. Be sure not to crease ribbon.
10. Watch for the green LED on the card reader to flash four times while you connect the battery wire to the PCB.
The green light indicates that the PCB has reset.
Important: The battery wire should be the last connection made to the PCB.
11. With the dead bolt retracted, insert the long end of the dead bolt spindle assembly through the PCB switch
cam hole and into the mortise dead bolt hub. The indicator marks on the switch cam should be at the right
(3:00 position) when the mortise dead bolt is retracted (see Fig. 6). The retaining ring should rest on the switch
cam when fully inserted (the proper positioning of the cam will allow the door to be opened when the dead bolt
is retracted and block entry when the dead bolt is thrown for privacy, except when emergency keycards are used).
Position dead bolt spindle assembly into cam assembly.
Important: As illustrated in Fig. 3, be sure that the cam is in correct orientation.
12. Install the inside escutcheon with the thumb turn pointed upward.
Fig. 6
Battery Wire
Motor Wire
© SAFLOK, all rights reserved.
(continued)
Route the ribbon over the
battery. Do not crease
ribbon connector.
Battery
Ribbon
Cable
Dead Bolt
Spindle
Position for the ADB mortise
lock assembly
Position for the STD mortise
lock assembly
3:00 Position
ADB Mortise
OR
6:00 Position
Standard Mortise