Cleaning The Spray Arms - Miele HG07-W Operating Instructions Manual

Table of Contents

Advertisement

Cleaning and care

Cleaning the spray arms

Particles of food can get stuck in the
spray arm nozzles and bearings. The
spray arms should therefore be
inspected regularly (approx. every 2–
4 months).
Damage due to soiling entering
the circulation system.
Without filters, soiling can enter the
circulation system and cause a
blockage.
Do not run a wash programme
without the lower spray arm or
without the filters.
When cleaning the filters and spray
arms, make sure that coarse soiling
cannot get into the circulation
system.
 Switch the dishwasher off.
Removing the upper and middle
spray arms
 Take out the 3D MultiFlex tray (if your
dishwasher is fitted with one).
 Push the upper spray arm upwards to
engage the inner ratchet. Then
unscrew the spray arm by rotating the
screw thread anti-clockwise.
72
 Rotate the screw thread of the middle
spray arm clockwise  (see diagram)
and remove the spray arm .
Removing the lower spray arm
 Remove the lower basket.
 Rotate the screw thread of the lower
spray arm anti-clockwise  and pull
the spray arm upwards to remove .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents