Installation
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (3) from the socket on the circuit board of the air outlet
unit.
➤ Connect the two cables of the remote light switch to the 2-pin plug (3).
➤ Insert the 2-pin plug (3) into socket on the circuit board.
12 Vg cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 Vw voltage supply is not connected.
To do this, proceed as follows:
➤ Connect the positive cable and the negative cable to the battery.
Connecting the circuit board
See fig. e
➤ Insert the 12-pin plug (1) in the socket (3) on the circuit board of the air outlet unit.
➤ Connect the 2-pin connector plug (2) to the wire from CI-Bus master panel
(optional).
8.6
Installing the air outlet unit Chillout ADB
See fig. f
➤ Attach the air outlet unit to the (1) fastening frame using the short fastening
screws.
See fig. g
➤ Install the air filter in the specified sequence.
See fig. h
➤ Fit the filter covers.
➤ Enter the new vehicle height and weight in the vehicle documents.