OZ   C HARGE   G RUNT   S ERIES   –   W ORKSHOP   B ATTERY   C HARGER  
 
CONTROL  LAMPS  &  ERROR  DESCRIPTIONS  
The   c ontrol   l amps   o n   t he   t op   o f   t he   c harger   i ndicate   d ifferent   o perating   a nd   e rror   s tatuses:  
 
Orange   L EDs   i ndicate   t he   s elected   c harger   f unction  
Green   L EDs   i ndicate   t hat   t he   b attery   h as   f inished   c harging  
The   r ed   L ED   i ndicates   a n   e rror  
 
LED  
 
Blinking  
 
Alternate   b linking  
 
Steady   l ight,   o range   d immed  
 
Steady   l ight  
 
CHARGING  PROCESS  
Batteries   a re   c harged   f ully   a utomatically,   m onitored   b y   a   m icro-­‐processor   w ith   a   t hree-­‐stage   ( four-­‐stage   f or  
Standard   T ype   b atteries)   c harge   c haracteristic   f or   o ptimum   a nd   g entle   t reatment   o f   t he   b atteries.   A fter   c onnecting  
the   b attery   t o   t he   P WC,   t he   c harging   p arameters   f or   t he   b attery   c an   b e   a djusted   b y   s electing   t he   t ype   o f   b attery  
(Standard   o r   G el/AGM).   F or   t he   O C-­‐W122470P   m odel,   y ou   c an   s elect   t hese   b attery   t ype   f or   1 2V   o r   2 4V.   P lease  
ensure   y ou've   s elected   t he   c orrect   c harge   o utput   t o   s uit   y our   a pplication.  
 
Bulk   C harge   -­‐   C harging   w ith   c onstant   c urrent   ( Orange   L ED   l ights   u p)  
The   m aximum   c harging   c urrent   i s   u sed   t o   c harge   t he   b attery,   d epending   o n   i ts   c harged   s tatus,   s o   a s   t o   s tore   a s   m uch   e nergy   a s  
quickly   a s   p ossible   i n   t he   b attery.   I f   a   b attery   t hat   h as   b een   t otally   d ischarged   i s   a ttached   t o   t he   c harger,   t he   c harger   w ill   s tart  
charging   w ith   r educed   e nergy   t o   a void   d amaging   t he   b attery.   O nce   t he   m ain   c harging   v oltage   h as   b een   r eached   1 4.4V   ( 28.8V)  
to   1 4.7V   ( 29.4V)   ,   d epending   o n   t he   t ype   o f   b attery,   t he   c harger   s witches   t o   t he   n ext   c harging   p hase.  
 
Absorption   C harge   -­‐   C harging   w ith   c onstant   v oltage   ( Orange   L ED   l ights   u p)  
The   b attery   b ecomes   f ully   c harged   i n   t his   p hase.   V oltage   i s   m aintained   a t   1 4.4V   ( 28.8V)     ( when   s et   t o   G el/AGM)   o r   1 4.7V  
(29.4V)     ( when   s et   t o   S tandard).   A s   t he   c harge   i ncreases,   t he   c urrent   c ontinuously   d ecreases   a nd   a pproaches   a   l ower   l imit   t hat  
depends   o n   t he   t ype   a nd   s ize   o f   t he   b attery.   A s   s oon   a s   i t   d rops   b elow   t his   v alue   o r   e xceeds   t he   s et   m inimum   c harging   p eriod  
the   c harger   s witches   t o   F loat   m ode   ( or   E qualisation   C harge   i f   t he   S tandard   b attery   t ype   i s   s elected).  
 
Equalisation   C harge   –   R estores   f ull   c apcity   ( Orange   L ED   l ights   u p)     -­‐   S tandard   s etting   o nly  
A   w ell   p roven   p rocess   t hat   c arefully   o vercharges   t he   b attery   t o   r estore   i ts   f ull   c apacity.   T he   E qualisation   s tage   o ccurs  
for   S tandard   B attery   t ype   s election   o nly.   D uring   t his   s tage,   t he   v oltage   w ill   b e   m aintained   a t   1 5.5V   ( 31V)   f or   a round  
1   h our   b efore   s witching   t o   F loat   m
 
Float   -­‐   M aintenance   c harging   w ith   r educed   v oltage   ( Green   L ED   l ights   u p)  
The   c harging   v oltage   i s   r educed   t o   1 3.8V   ( 27.6V)   i n   o rder   t o   m aintain   t he   c harge   f or   a n   u nlimited   p eriod   o f   t ime,  
whereby   t he   p hysically   i nduced   s elf-­‐discharge   i s   c ompensated   a nd   t he   b attery   i s   m aintained   i n   a   f ully   c harged   s tate  
   
until   i t   i s   d isconnected.
 
 
STATUS  
ode.  
Oz   C harge   G RUNT   S eries   W orkshop   C harger   O wner's   M anual     -­‐   V 1.0   0
DESCRIPTION  
Charger   s etting   f or   t his  
LED   h as   b een   s elected  
Incorrect   b attery   v oltage  
has   b een   s elected  
Charging   p rogram   h as  
been   s elected,   b ut   n o  
battery   i s   c onnected  
Battery   i s   f ully   c harged  
4/16  
ACTION  
 
Set   t he   c orrect   b attery  
voltage   ( see   p age   6 )  
Connect   b attery   o r   s et  
power   s upply   f unction  
Battery   c an   b e  
disconnected   a nd   u sed  
4  